![Raven CRX ROS+RS1 Installation Manual Download Page 19](http://html.mh-extra.com/html/raven/crx-ros-rs1/crx-ros-rs1_installation-manual_788979019.webp)
PAGE 19/36 |
Installation manual
|
016-8000-028EN
|
Rev. B
CRX/ ROS INSTALLATION | CRX/VIPER 4+ ROS - RS1 | RAVEN EUROPE GENERIC
1.2.8
WHEEL ANGLE SENSOR
For a correct operation of the Raven system a wheel
angle sensor is necessary. In various tractor types a
factory fitted wheel angle sensor is already mounted
on the front axle. For these tractor types a
‘spy cable’ is
available at Raven to use the factory fitted wheel angle
sensor for the Raven system. In this case it is not
necessary to install a Raven wheel angle sensor. Ask
Raven for more information about the availability for a
specific tractor brand or type.
1.2.9
MOUNTING SPY-CABLE
Take the following steps to mount a wheel angle
sensor spy-cable:
1.
Follow the cable from the wheel angle sensor
on the front axle of the tractor to the first
connection in this cable.
2.
Disconnect the connectors.
3.
Connect the spy-cable in between the
connectors.
4.
Connect the wheel angle sensor 5M cable to
the M12 connector of the spy-cable.
5.
Mount the spy-cable in a clean and dry
position (Figure 14).
FIGURE 14 SPY CABLE MOUNTED ON A CNH
TRACTOR