Manual #016-0171-081 Rev. B 07/08
9.
Connect a CAN terminator P/N 063-0172-369 to the end of the CAN
cable P/N 115-0171-362.
Note:
If the machine already has a CAN
system installed, remove the terminator from
the existing CAN system and move it to the
CAN cable previously installed. If no CAN
system exists on the machine, refer to Chapter
3 and use on of the terminators contained in
the CAN Tee With Power kit P/N 117-0159-
923.
10.
Connect the CAN system.
a.
Connect the single end of the CAN cable P/N 115-0171-326 to
the CAN bus or to the CAN PWR Tee system installed in
Chapter 3.
11.
Connect power and ground.
a.
Wire the red power wire to a clean source of switched 12 volt
power.
b.
Connect the white ground wire directly to the battery ground.
12.
The CAN AccuBoom installation is now complete.