AccuFlow™ Vortex and AccuFlow™ HP+ Installation: 1.5” Gauge Tree and Valve Assembly
23
ACCUFLOW™ VORTEX AND ACCUFLOW™ HP+ INSTALLATION
CHECK VALVE ASSEMBLY (FOR MULTIPLE SECTION VALVES ONLY)
FIGURE 9. Check Valve Assembly
1. Apply PTFE thread sealant to all threaded joints.
2. Install the pipe nipple into the top of the fitting tee.
3. Attach the check valve to the pipe nipple with the flow direction as shown in Figure 9.
NOTE:
Refer to the spare parts list in Chapter 8,
System Diagram and Replacement Parts
for a list of
replacement parts.
Pipe Nipple
Check Valve
Fitting Tee
Gauge Tree
1/4” Bleed Valve
Flow Dir
ecti
on
Relief Valve