b.
Connect the high current power wire (10 ga red wire in Parallel
AccuBoom Cable P/N 115-0171-598) to a fused connection from
the fuse box.
c.
Connect the logic power wire (small red wire in Parallel
Accuboom Cable P/N 115-0171-598) to a source of clean switched
power.
6.
Connect the orange wire from the Parallel AccuBoom Cable P/N 115-
0171-598 to the master boom enable switch on the machine.
a.
Pull the joystick cable connectors out from under the side console.
b.
Identify the master spray/hold switch connector.
c.
Disconnect the two pin weatherpac connectors.
d.
Plug in the orange “Tee” connector from the Parallel AccuBoom
Cable P/N 115-0171-598 into the weatherpac connectors.
e.
Return the wires and connectors to their location under the side
console.
Master Spray/Hold
Switch Connection
Manual #016-0171-013 Rev. C 01/07
10