Master/Override Switch
The master switch toggles all section switches on or off. When the master switch
is in the ‘ON’ position, each section will function according to the corresponding
section switch (see the “3-Way Selectable Section Switches” below). Toggle the
master switch to the ‘OFF’ position to turn all boom or implement sections off.
Hold the master switch to the ‘OVERRIDE’ position to temporarily override any
sections controlled by an optional AccuBoom system on.
3-Way Selectable Section Switches
The section switches may be used to toggle up to ten individual sections. Raven
field computers are also capable of controlling additional sections using the
section mapping feature to group sections to the same switch. Refer to the field
computer
Installation and Operation Manual
for additional information.
Note:
Envizio Pro software version 3.5 or newer or a Viper Pro controlling an
OmniSeed system are required to access section mapping. Contact a local
Raven dealer for additional information.
Each of the ten section switches may be toggled individually to one of the three
following positions:
• ON - manually control the section on. AccuBoom control of the section is
disabled and will not automatically control this section based on coverage, zone
maps or field boundaries.
• ACCU - AccuBoom automatic section control is enabled for the section. If
installed and properly set up for the active job, the AccuBoom features will
automatically turn sections on or off based upon previous coverage, zone maps
or field boundaries created or active in the job.
Refer to the control console or field computer operation manual for more
information about using the AccuBoom system.
• OFF - manually control the section off. This section will remain off regardless of
AccuBoom control features.
Note:
Leave the section switch in the off position for any sections not connected
or controlled by the Raven control console or field computer.
Product Control Switches
Each of the five product control switches may be toggled individually to one of the
three following positions:
• AUTO - The product rate will automatically be controlled by the product control
console or field computer based on the vehicle speed and programmed target
rate. Refer to the control console or field computer operation manual for
information on programming a target rate for controlled products.
• MAN - The product rate must be manually controlled by the operator. The
Raven control console or field computer will not adjust product rate based on
vehicle speed or section status.
• OFF - The programmed product is off. Corresponding control valves, injection
pumps or spinners will remain closed or will not run regardless of section or
master switch changes.