Page 1: ...016 0171 682 Rev A 11 19 E31630 Copyright 2019 ISOBUS Auxiliary Display Guide ...

Page 2: ...en Industries shall not be held responsible for any modifications or repairs made outside our facilities nor damages resulting from inadequate maintenance of this system As with all wireless and satellite signals several factors may affect the availability and accuracy of wireless and satellite navigation and correction services e g GPS GNSS SBAS etc Therefore Raven Industries cannot guarantee the...

Page 3: ... be equipped with multiple Raven Rate Control Modules RCMs If the system consists of multiple RCMs the operator will need to determine which RCM is assigned to which tank The Raven ISOBUS Auxiliary Display recognizes RCMs by serial number NOTE If the location of the RCM is uncertain the serial number may be viewed from the in cab UT VIEW RCM SERIAL NUMBER 1 Choose the RCM working set from the UT f...

Page 4: ...sired RCM is displayed press the ESC button to return to the main menu NOTE The Serial Number is physically found on the face of the RCM FIGURE 2 Display Information READ AND ZERO TANK WEIGHT VIA TANK BIN INFO FOR DRY PRODUCTS 1 Power on the Auxiliary Display by pressing the esc button on the front of the monitor 2 Using the UP DOWN or LEFT RIGHT arrows to highlight the Tank Bin Info menu 3 Touch ...

Page 5: ...antity Readings 6 To zero out the product weight press the button directly below ZERO Then press ok to accept that the tank will be zeroed out Press CANCEL to cancel the operation NOTE Zero will only be available if scales are equipped on the machine If there are no scales read the calculated level based on what has been entered in the RCM for that product FIGURE 5 Zero Out Warning and Zeroed Out ...

Page 6: ...en FIGURE 7 Tank or Bin Information Menu 4 The weight of the previously selected product will be displayed 5 To change the selected product press the LEFT RIGHT arrows NOTE The percentage on the left side will display the percentage of product in the tank based on the tank capacity The tank capacity is set from the in cab monitor 6 Press the NEXT or PREV buttons to toggle screen view The toggled v...

Page 7: ...ings NOTE The FLOW RATE reading indicates the rate of liquid product flowing into the tank 7 On the Product Quantity screen for liquid products press the EDIT button to change the percentage of the tank or hit REFILL to get back to 100 FIGURE 9 Edit Product Quantity for Liquid Product ...

Page 8: ... displayed 5 To change the selected SCALE press the LEFT RIGHT arrows FIGURE 11 Scale Weight 6 To zero out the product weight press the button directly below ZERO Then press ok to accept that the tank will be zeroed out Press CANCEL to cancel the operation NOTE The TARE button can be used when a single scale is monitoring multiple bins and it is desired to monitor a specific load 7 Press the NEXT ...

Page 9: ...emote monitor by pressing the esc button on the front of the monitor 2 Using the UP DOWN or LEFT RIGHT arrows highlight the box Rate Calibration blue FIGURE 13 Rate Calibration Menu 3 Press ok to enter the Rate Calibration screen 4 The Calibration Information of the previously selected product will be displayed 5 Press the LEFT RIGHT arrows to change the selected product if necessary ...

Page 10: ... 15 Calibration Warning 9 Press ok to continue or press the esc button to exit the calibration NOTE Ensure the machine is ready to apply product 10 After selecting ok the Select Sections to Activate page will be displayed 11 Use the arrow keys to highlight the sections from which to dispense product for the catch test and then press ok to select the sections NOTE A circle around the number will re...

Page 11: ...ainer or the estimated test time NOTE For High Rate Products a 5 gallon approximately 19 L container can hold roughly 20 lbs approximately 9 kg of product If using a 5 gallon approximately 19 L container a desired weight of 20 lbs approximately 9 kg can be used For Low Rate Products the estimated test time must be equal to or greater than 10 mins If the test takes less than 10 mins increase the De...

Page 12: ...ess than 10 mins the NEXT button will not appear Adjust the calibration values accordingly FIGURE 18 Edit Catch Test Value 18 If no product has been measured though the meters use the PRIME button to prime the meters and repeat as necessary Make sure the container is empty before proceeding to the next step FIGURE 19 Priming and Start Catch Test 19 Press the START button to begin metering product ...

Page 13: ...ensed product NOTE If using a digital scale please remember to zero out the weight of the container or weigh the container before the calibration so the weight of the container can be subtracted from the total weight 22 Using the LEFT RIGHT and UP DOWN arrow enter the actual amount of product applied When the desired value is entered press the ok button FIGURE 21 Enter Catch Weight 23 The Catch Te...

Page 14: ...e off line or the Current ECU RCM is not selected Ensure the desired RCM is selected 1 Press the esc button on the front of the monitor to exit to the main menu 2 The Diagnostics menu will be highlighted 3 Press ok to enter the Diagnostics Info screen 4 Press either button below Next ECU to toggle between RCMs NOTE If the CURRENT ECU SERIAL displays 0 this means that a RCM is not selected 5 Once t...

Page 15: ...urn Tractor OFF 2 Turn Universal Terminal UT OFF 3 Ensure that everything is powered down 4 Check IBBC connector at the back of the Tractor 5 Start Tractor 6 Turn on Universal Terminal UT 7 Check Raven ISOBUS Auxiliary Display operation 8 If problem still exists unplug and plug back in the Raven ISOBUS Auxiliary Display from the main harness and repeat steps 1 through 7 9 If unsuccessful contact y...

Page 16: ... the original owner and is non transferable HOW CAN I GET SERVICE Bring the defective part and proof of purchase to your Raven dealer If the dealer approves the warranty claim the dealer will process the claim and send it to Raven Industries for final approval The freight cost to Raven Industries will be the customer s responsibility The Return Materials Authorization RMA number must appear on the...

Page 17: ...nsible for damage to any associated equipment or products and will not be liable for loss of profit labor or other damages The obligation of this warranty is in lieu of all other warranties expressed or implied and no person or organization is authorized to assume any liability for Raven Industries Damages caused by normal wear and tear misuse abuse neglect accident or improper installation and ma...

Page 18: ... not have a serial tag the kit it came in must be registered instead WHERE CAN I REGISTER MY PRODUCT FOR THE EXTENDED WARRANTY To register go online to www ravenhelp com and select Product Registration HOW LONG IS THE EXTENDED WARRANTY COVERAGE PERIOD Raven Applied Technology products that have been registered online are covered for an additional 12 months beyond the Limited Warranty for a total c...

Page 19: ...and the claim itself Raven Industries will at our discretion repair or replace the defective product and pay for the standard return freight regardless of the inbound shipping method Expedited freight is available at the customer s expense WHAT IS NOT COVERED BY THE EXTENDED WARRANTY Raven Industries will not assume any expense or liability for repairs made outside our facilities without written c...