REVAC 

     

 

 
 

 

Conventional PA System 

 
 
 

Installation, Commissioning & Operating 

user Manual

 

 

 
 

 

 

 

 

Summary of Contents for REVAC

Page 1: ...REVAC Conventional PA System Installation Commissioning Operating user Manual...

Page 2: ...1 0 01 Page 2 Table of Contents 1 Product Description 3 2 Control and Indications 5 3 Program 6 Suppressed Events 6 Mode 7 Alarm Mode 7 Mic Mode 8 Music Mode 8 DVA Mode 9 Alarm DVA 10 Program 10 Advan...

Page 3: ...nt and common announcement through microphones Product Features Operates on 220V 50 Hz AC Main switch mode power supply Standby backup 24VDC battery 19 Rack mountable System ON Power Fault Common faul...

Page 4: ...r 24VDC Charging Circuit Charging Voltage 28 V 0 2V Nominal Charging Current 1 2A Max Temperature Operating Temperature 0 49 C 32 120 F Relative Humidity 93 2 RH non condensing at 32 2 C 90 3 F DC Out...

Page 5: ...01 Page 5 2 Control and Indications LED Indication System ON Green Power Fault Yellow Common Fault Yellow Allcall Yellow Alarm Red MIC Yellow Connection diagram REVAC is compatible with Conventional R...

Page 6: ...he menu 2 Use Enter Key to select the menu list and conform the change of the status D E 2 Erase Recording Time 020 Sec Erasing 5 Advanced 5 1 Set Slave Address 0 5 2 Configure Slave 6 About REVAC Ver...

Page 7: ...e The REVAC has Four types of mode namely Alarm MIC Music DVA In this modes Display as shown below 2 Mode Ala rm Alarm Mic Music DVA Alarm Mode The alarm mode shall be selected manually from keypad or...

Page 8: ...onding LED s and also shown in LCD If there is a Fault LCD screen display will be shown below M Fault X Y Type of Fault Where M represents in Mic mode In Normal System Healthy screen the LCD display w...

Page 9: ...Mode The DVA mode is used to Play Recorded Messages information to particular zone by selecting that particular zone with continuation of DVA mode switch If the DVA mode is selected manually then the...

Page 10: ...etected Recorded Message will played Program Access to programming is possible only by Admin password Default Password 54321 By selecting the number 4 from the menu screen system enters into the progr...

Page 11: ...advanced mode Here there are two sub headings Set Slave Configure are available A Set Slave The LCD Display of the Set Slave is shown below 5 1 Set Slave Address B Configure The LCD Display of the Con...

Page 12: ...04 9599 Email marketing ravelfire com Web www ravelfire com DATE TEST CERTIFICATE We hereby certify that the items detailed hereon have been manufactured inspected and electrically tested to ensure th...

Page 13: ...period returned to the company under a written intimation and which to the company s satisfaction to be found defective The company reserves the right to decide the workplace for the repair work The...

Page 14: ...RE DD UM REVAC 1 0 01 Page 14 Ravel Electronics Pvt Ltd 150A Electronic Industrial Estate Perungudi Chennai 600096 India Web www ravelfire com Email marketing ravelfire com...