![Ravas RPW EL Operation Manual Download Page 2](http://html1.mh-extra.com/html/ravas/rpw-el/rpw-el_operation-manual_3826598002.webp)
2
THE WEIGHING SYSTEM FOR ELECTRIC PALLET TRUCKS
1. TAKING THE SYSTEM INTO OPERATION
To activate the weighing system, turn it on using the on/off (
) button on the
terminal.
After 3 to 5 minutes the electronics and load cells have reached the operational
temperature. Before this, inaccuracies of up to ca. 0.3% may occur.
It is recommended not to lift loads before the zero-point correction has been
executed.
2. USE
The
indicator’s power is supplied by the truck’s battery. When the voltage of the
battery becomes too low, a message will be shown and the indicator switches off
automatically.
The weight must be lifted freely: the weight may not touch parts of the truck body or
other pallets:
Wrong way of lifting the load
Correct way of lifting the load
The accuracy of the weighing system diminishes with circa 0.1% per degree starting
from a tilted position of 2°. This effect also occurs with pits/potholes in the floor. An
even floor is optimal.