Ravas RPW EL Operation Manual Download Page 2

 

THE WEIGHING SYSTEM FOR ELECTRIC PALLET TRUCKS  

 
 
 
 

1.  TAKING THE SYSTEM INTO OPERATION 

 
To activate the weighing system, turn it on using the on/off (

) button on the 

terminal. 
 
After 3 to 5 minutes the electronics and load cells have reached the operational 
temperature. Before this, inaccuracies of up to ca. 0.3% may occur. 
 
It is recommended not to lift loads before the zero-point correction has been 
executed. 
 
 
 

2.  USE

 

 
The 

indicator’s power is supplied by the truck’s battery. When the voltage of the 

battery becomes too low, a message will be shown and the indicator switches off 
automatically. 
 
The weight must be lifted freely: the weight may not touch parts of the truck body or 
other pallets: 
 

 

 

 

 

 

              Wrong way of lifting the load 

 

 

Correct way of lifting the load 

 

 

 

 
 
The accuracy of the weighing system diminishes with circa 0.1% per degree starting 
from a tilted position of 2°. This effect also occurs with pits/potholes in the floor. An 
even floor is optimal. 
 
 