background image

 

USER MANUAL

 –

 

i

Forks

 

Table of contents 
 

 

 

 

 

 

 

 

 

 

               

page 

 
1. Introduction   

 

 

 

 

 

 

 

 

 

2. Warnings & Safety measures  

 

 

 

 

 

 

 

3. Exploded-view & parts list 

 

 

 

 

 

 

 

 

4. System setup  

  

 

 

 

 

 

 

 

 

 

4.1 Installation the 

i

Forks

 

 

 

 

 

 

 

 

 

4.2 Locking the 

i

Forks   

 

 

 

 

 

 

 

 

4.3 Installing the indicator 

 

 

 

 

 

 

 

7

 

4.4 Placing battery modules in the 

i

Forks 

 

 

 

 

 

 

 

4.5 Switching on the 

i

Forks 

 

 

 

 

 

 

 

 

4.6 Switching on indicator 

 

 

 

 

 

 

 

 

4.7 Switch off the system 

 

 

 

 

 

 

 

5. Changing the batteries 

 

 

 

 

 

 

 

 

10 

5.1 Low battery indication 

i

Forks

  

 

 

 

 

 

 

10 

5.2 Changing the batterypacks of the

 

i

Forks

 

 

 

 

 

 

11

 

5.3 Changing the batteries of the indicator 

 

 

 

 

 

13 

6. Use    

 

 

 

 

 

 

 

 

 

 

14 

 

6.1 Use (accurate weighing) 

 

 

 

 

 

 

 

14 

 

 

6.1.1 zero check before a weighing

  

 

 

 

 

 

14 

 

6.2 Level correction 

 

 

 

 

 

 

 

 

15 

6.3 Establish Bluetooth communication and weigh!  

 

 

 

 

16 

 

6.4 Auto shut-off indicator 

 

 

 

 

 

 

 

17 

 

6.5 Auto shut-off 

i

Forks

    

 

 

 

 

 

 

 

18 

 

6.6 Indicator functions   

 

 

 

 

 

 

 

19 

 

6.7 Error messages 

 

 

 

 

 

 

 

 

21 

 

6.8 Gross / tare / net weight 

 

 

 

 

 

 

 

22 

 

 

6.8.1  Net weighing: automatic tare 

 

 

 

 

 

22 

 

 

6.8.2  Net weighing: manual tare PT 

 

 

 

 

 

24 

6.9 Adding and reset 

 

 

 

 

 

 

 

 

27 

 

6.10 KG-LB switch 

 

 

 

 

 

 

 

 

29 

 

6.11 User settings 

 

 

 

 

 

 

 

 

30 

 

6.12 Changing the time and date on the printout   

 

 

 

 

33 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

Summary of Contents for iForks

Page 1: ...u about the fact that this RAVAS product is 100 recyclable on the basis that the parts are processed and disposed off in the right manner More information can be found on our website www ravas com Rev...

Page 2: ...ons or from negligent operation or assembly even if this is not expressly stated in this instruction manual In light of our policy of continuous improvement it is possible that details of the product...

Page 3: ...indication iForks 10 5 2 Changing the batterypacks of the iForks 11 5 3 Changing the batteries of the indicator 13 6 Use 14 6 1 Use accurate weighing 14 6 1 1 zero check before a weighing 14 6 2 Leve...

Page 4: ...done to the operator because of the presence of the indicator in the cabin Any modifications done to the system must be approved in writing from the supplier prior to any work being completed It is t...

Page 5: ...tooth transmitterboxes set with nr 1 and 2 SS LABEL WF SMALL 1 RAVAS 14 Coverplate forks left Coverplate forks right MP CP RF LEFT FEM2A or 2B MP CP RF RIGHT FEM2A 1 1 RAVAS 15 Socket head screw M8 x...

Page 6: ...USER MANUAL iForks 6 4 System setup 4 1 Installing the iForks The standard forks must be taken from the carriage plate The iForks are placed on the carriage plate Locking the iForks 1 2...

Page 7: ...or Find a suitable position for the indicator 1 at the cabin s roof 2 at the right side of the cabin mounted onto a side rail 3 at the dashboard Installation of the indicator bracket support The indic...

Page 8: ...osition the batterypacks in both forks 3 Click the batterypacks into the battery holders 4 Push the locking clips down to secure the batterypacks 4 4 Switching on the iForks 1 Switch on the forks by p...

Page 9: ...2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR Start up the indicator Press the on off key e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 5 sec 1 2 3 Weigh Switch off the indicator by pressing the o...

Page 10: ...F2 or both will start blinking in the display The blue LED s on the relating fork will start blinking very slowly twice every 10 sec The iForks will switch off automatically after 10 minutes FUNCTION...

Page 11: ...hanging the batterypacks of the iForks 5 2 1 Take out both batterypacks 5 2 2 Change the D Cells inside the batterypacks 1 Remove the 6 Philips head screws M3 x 25 2 Remove the top housing of the batt...

Page 12: ...rger Charge the battery for at least 8 hours This will prevent loss of battery capacity Check by reading the battery pack label to make sure this batterypack is equiped with recharable batteries Only...

Page 13: ...voltage stabilizator board Use a M6 hex key to release the bolts of the indicator housing Open the indicator housing and remove the empty batteries Place new batteries Be sure the batteries are positi...

Page 14: ...Use 6 1 Use accurate weighing OK 0 max 40 C 105 F min 10 C 15 F 0 M1 M1 3 5 min After 3 to 5 minutes the load cells have reached the operational temperature Don t lift loads before the zero point corr...

Page 15: ...load and does not make contact with other obstacles When de indicator doesn t show automatically the zero then a manual zero correction has to be done by pressing short on the key 0 e1 e2 e3 F1 F2 NE...

Page 16: ...eady to weigh 6 5 sec e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR Before each weighing check t...

Page 17: ...ut off indicator 2 5 4 1 no action Countdown starts Press any key during to cancel auto shut off and go back to the weighing mode e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR Indicator off e1 e2...

Page 18: ...o shut off iForks Switch on the iForks press the blue button below both batterypacks 2 3 4 1 Restart the indicator Press the on off key e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR iForks off Ind...

Page 19: ...e 1 option multi range e2 displayed weight shown is in range 2 option multi range e2 displayed weight shown is in range 3 option multi range F1 Fork 1 setpoint 1 is activated option relay output F2 Fo...

Page 20: ...e total increase the value of the digit flashing sampling a piece weight enter a piece weight shift to the next digit on the left On switch Off switch And change to lb and kg clear entry Important Ope...

Page 21: ...nded install jumper JP1 attention after this action a complete new calibration and stamping of the system is necessary Automatic Err99 ErrF1 ErrF2 L _ ErrCS F1 F2 Action only allowed in start up units...

Page 22: ...8 1 Net weighing automatic tare 2 1 3 4 The indicator is set to zero The NET pointer shows that the tare weight is activated 1 2 3 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET...

Page 23: ...y shows the net value of the weighed load The gross weight is displayed again 1000 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 6 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 1000 e1 e2 e3 F...

Page 24: ...PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 6 8 2 Net weighing manual tare PT 2 1 6 3 4 5 Press the PT key for 3 sec Press the up or down key until the desired value is reached 5x...

Page 25: ...r lights up When the iForks are completely unloaded the tare value is displayed negatively e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 1000 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e...

Page 26: ...USER MANUAL iForks 26 14 13 The gross weight is displayed again e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR...

Page 27: ...lly If a printer is installed a printout will be made The gross net and tare weights are printed 250 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR...

Page 28: ...e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 3 sec CLR 8 7 9 The subtotal can be checked by pressing the TOTAL key for 3 sec e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR TOTAL KG LB CLR RES...

Page 29: ...USER MANUAL iForks 29 6 10 KG LB switch 2 1 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR kg KG LB 5 sec e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR lb...

Page 30: ...ec EXIT without SAVING EXIT SAVE Back to weigh mode Back to weigh mode e1 e2 e3 F1 F2 NET ID CODE PT TOTAL PCS KG LB CLR 10 sec The user menu can be entered by pressing the TOTAL key for 10 sec These...

Page 31: ...USER MANUAL iForks 31 Set the auto shut off time indicator delay time in minutes Set backlight intensity in 0 min indicator always on 0 backlight off...

Page 32: ...USER MANUAL iForks 32 De activate Com Port 2 De activate Com Port 1 It is not possible to de activate Com Port 1 for iForks forks...

Page 33: ...ue until the required value is reached To accept the new value press ENTER The display will show m_00 or the previous minute time setting The right digit flashing Repeat the above procedure to accept...

Page 34: ...2328 ISO 2330 EN 1726 1 paragraph 5 6 5 In respect of a non automatic weighing instrument Manufacturer RAVAS Europe B V Model iForks Description weighing forks This declaration of conformity is valid...

Reviews: