USER MANUAL
–
i
Forks-32 (XT)
23
5.7 Error messages
ERROR MESSAGES
Display Meaning
Out of error mode
Err01
Err02
Err03
Err04
Err06
Err08
Err09
Err10
Err14
CAL-J
Err98
Err99
ErrF1
ErrF2
----
Err_L
+F1
+F2
tiP
SidE
OimL
ntEP
SCALL
Er_F1
Er_F2
ESoFt
EConF
Load cell signal is unstable
Overload on full scale
Gross negative. This action is not allowed
Out of zero range
Input signal too high
Calibration out of range (negative)
Calibration out of range (signal too low)
Calibration count 2nd (3rd) point lower than count 1st (2nd)
point
Setpoint value 2 < setpoint value 1. This is not allowed
Legal for trade version: action not allowed
Calibration point must be higher than previous one
Action only allowed in start-up units
Problem with fork 1 (no communication)
Problem with fork 2 (no communication)
Loadcell signal negative
Forks are out of level (only legal-for-trade version)
Battery of indicator is empty
Battery of fork 1 is empty
Battery of fork 2 is empty
too large load on tip of forks (only legal for trade version)
too large load on one fork (only legal for trade version)
action not allowed (only legal for trade version)
action not allowed (only legal for trade version)
audit trail no out of range
too few samples for measurement
too few samples for measurement
Wrong combination of firmwares
P96 not set
Automatic
Automatic after removing weight
Automatic
Press any key
Automatic after correcting input
Automatic
Automatic
Automatic
Automatic
When action is intended, remove jumper JP1
( attention: after this action a complete new
calibration and stamping of the system is
necessary )
Automatic
Automatic
Restart indicator. Restart forks & indicator
Restart indicator. Restart forks & indicator
Lift up the forks from the ground
Put the forks into horizontal position
Replace the 4 AA batteries
Replace the D-cells in both battery packs or
charge both battery packs
Replace the D-cells in both battery packs or
charge both battery packs
change load placement
change load placement
automatic
automatic
Contact RAVAS Service department
Wait for improvement of the bluetooth connec-
tion (try moving the mast to lower position)
Wait for improvement of the bluetooth connec-
tion (try moving the mast to lower position)
Contact your dealer
Contact your dealer
DISPLAY MESSAGES
BltF1
BltF2
Successful Bluetooth link with fork 1
Successful Bluetooth link with fork 2
No error
No error
Display Meaning