INSTALLATION AND SERVICE INSTRUCTIONS
SAX100 SOLID STATE POWER AMPLIFIER
D E S C R I P T I O N :
The SAX100 is a 100 watt solid state power amplifier with ½ Amp. switched and 0.1 Amp. direct auxiliary D.C.
power supplies included. The unit is provided with a power relay which controls the amplifier, the ½ Amp. D.C. out-
put, and the A.C. receptacles from a remote Off-On switch.
To secure the best performance it is suggested that the following instructions be read very carefully. Upon re-
ceipt of the amplifier the packing list should be checked to determine if all items have been received in good con-
dition. Any physical damage found should be reported at once to the transportation company as all claims for damage
must be made by the consignee. The amplifier should be tested immediately upon receipt as any damage due to rough
handling by the transportation company should also be reported and claim filed for concealed damages.
S P E C I F I C A T I O N S :
Rated Output:
100 watts RMS
Peak Output: 200 watts
Gain:
7 7 d b
Frequency Response: ± 2
db 25 - 20,000 Hz
Distortion: Less
than 3% at rated output 50 - 5,000 Hz
Noise Level: 80 db below rated output
Regulation: Less than 2 db
Operating Temperature Range:
O°F to 130°F
Input Impedance: 50,000
ohms
Input Voltage Required: 0.3
volt for rated power output
Output Impedance: 6.25
ohms, 25 volts isolated or 50
ohms, 70.7 volts isolated. 105/130
VAC, 60 Hz
Power Requirements:
No
Signal: 25
w a t t s
l/3
Rated Power Output: 165 watts
Rated Power Output & ½ Amp. D.C.: 275 watts
External Power Available: 28VDC ½ Amp.switched, and
Circuit Protection:
0.1 Amp. not switched, nega-
t ive ground.
3 Amp. slow blow line fuse. Auto-
matic reset thermal overload relay
on 120 volt, 60 Hz line. Automatic
reset thermal overload relay on ex-
ternal ½ Amp. DC line.
Tubes:
None. 17 Transistors, 3 Diodes
Dimensions: 19” panel, 7” high, 7” deep
Controls: Input
level adjustment
A.C.
Control Circuit:
Current Rating:
6 Amps. 120 VAC 720 watts
No. of Outlets:
3, relay controlled
Associated Items:
MAX 2400A
MCX 1400A
PAX 2400A
PAX 2100A
PBX 1400A
Note:
All tests conducted in accordance with EIA Standard SE-101-A where applicable.