Operation QUANTRON-K2
35
4
4.5.5
Calibration
In this menu, the flow factor is determined based on a calibration test and saved
in the control unit.
Perform the calibration:
Before spreading for the first time.
If the spreading material quality has changed significantly (moisture, high
dust content, cracked grain).
If a new type of spreading material is used.
Perform the calibration test with a running agitator and stationary machine
or
while driving a test track.
Place a collection container (tray, foil, etc.) on the ground under the
Single-disc spreader.
Entering the working speed:
1.
Call up the
Spreading mat. settings > Calibration
menu.
2.
Enter the average working speed.
This value is required to calculate the metering slide position during the
calibration.
3.
Press the
Enter key
.
The new value is saved in the control unit.
The
Calibration test
operating screen is shown on the display.
Running the calibration:
4.
Press
Start/Stop
(also press the Enter key for HydroControl).
The metering slide opens and calibration is started.
HydroControl
option: Agitator and spreading disc are started.
n
WARNING
Risk of injury when performing the calibration
Rotating machine components, the moving spreading width limiter
and ejected spreading material can cause injuries.
Ensure that all preconditions are been met.
before starting,
when interrupting and when finishing
calibration.
Observe the
Calibration
chapter in the operating manual of
the Single-disc spreader.
NOTICE
HydroControl
option: After pressing the
Start/Stop
key, an alarm window
appears.
Press the
Enter key
to activate the disc start.
Summary of Contents for QUANTRON-K2
Page 6: ...Table of Contents IV...
Page 10: ...User notices 1 4...
Page 26: ...Attachment and installation 3 20...
Page 72: ...Operation QUANTRON K2 4 66...
Page 90: ...Spreading operation using the QUANTRON K2 Control unit 5 84...
Page 94: ...Alarm messages and possible causes 6 88...
Page 96: ...Special equipment options 7 90...
Page 100: ...Index D...
Page 102: ......