Setting Parameter Interpretation
P01:
Backlight brightness. The darkest is level 1 & the brightest is level 3.
P02:
Mileage unit, 0
:
KM; 1
:
MILE.
P03:
Voltage level
:
24V, 36V, 48V.
P04:
T
urn off time
. 0 means the display will not turn off automatically; Other
numbers are the time turn off automatically. Range
:
1-60; unit: minute.
P05:
Switch PAS level: 0/1. 0: level 0-3; 1: level 0-5.
P06:
Wheel diameter
:
16-28. Unit: inch. 20 for 500W; 24 for 750W.
P07:
Speed gauge magnetic steel. Range 1-100.
P08:
Speed limit. Range 0-51km / h.
P09:
Zero start setting, 0
:
zero start; 1
:
Non-zero start.
P10:
Drive mode: 0/1/2.
0
: Power Drive : Power output is determined by the power file bit. (It is
invalid to change the data)