19
·
6. STARTING THE ENGINE
Recoil Starter
(1) Remove all the loads from the output side.
(2) Turn the fuel valve to the “ON” position.
(3) Turn the AC circuit breaker to the“OFF” position.
(4) Turn the choke lever to the“CLOSE” position.
Don’t close the choke when starting the engine in a warm state
(5) Turn the generator switch to the “ON” position.
(6) Pull the starter grip until a resistance is felt, then pull it out briskly.
(7) Turn the choke lever to the“OPEN” position after the engine is warm.
(8) Don’t use electric apparatus before setting circuit breaker to the“ON”
position.
Turn the generator switch to electric starting position and hold for
not longer than 5 seconds, or damage will be caused to the starting
motor. If starting fails, release the switch and wait for 10 seconds
before operating it again.
If the speed of the starting motor drops fast after running for a
period of time, it means the battery should be recharged.
STARTING THE ENGINE
Summary of Contents for R3000
Page 24: ...24 14 KYTKENT KAAVIO 2kW 2 5kW 2 7kW Vetok ynnistin...
Page 25: ...25 2kW 2 5kW 2 7kW Veto S hk k ynnistin...
Page 26: ...26 4kW 5kW 5 5kW 6kW Vetok ynnistin...
Page 27: ...27 4kW 5kW 5 5kW 6kW Veto S hk k ynnistin...
Page 28: ...2kW 2 5kW 2 7kW 4kW 5kW 5 5kW 6kW GENERATOR Owner s Manual...
Page 36: ...8 2 COMPONENT IDENTIFICATION 1 Recoil Starter COMPONENT IDENTIFICATION...
Page 37: ...9 2 Engine Type Serial Number COMPONENT IDENTIFICATION MODEL NO FINISHED PRODUCT NO SER NO...
Page 56: ...28 11 ELECTRIC STARTING 1 Component Identification ELECTRIC STARTING...
Page 61: ...33 14 WIRING DIAGRAM 2kW 2 5kW 2 7kW Recoil Starter WIRING DIAGRAM 2kW 2 5kW 2 7kW...
Page 62: ...34 2kW 2 5kW 2 7kW Recoil Electric Starter WIRING DIAGRAM 2kW 2 5kW 2 7kW...
Page 63: ...35 4kW 5kW 5 5kW 6kW Recoil Starter WIRING DIAGRAM 4kW 5kW 5 5kW 6kW...
Page 64: ...36 4kW 5kW 5 5kW 6kW Recoil Electric Starter WIRING DIAGRAM 4kW 5kW 5 5kW 6kW...