background image

Summary of Contents for R1250HIS-4

Page 1: ...3kW Owner s Manual GENERATOR ORIGINAL INSTRUCTION SILENT INVERTER GASOLINE ENGINE GENERATOR ...

Page 2: ......

Page 3: ...sed on the latest product information available at the time of printing The contents in this manual may be different from the actual parts due to revision and other changes Our company reserves the right to make changes at any time without notice and without incurring any obligation No part of this publication may be reproduced without our company s written permission This manual should be conside...

Page 4: ...SAFETY WARNINGS Personal safety and property safety of you and others are very important Please read these messages which is preceded by a symbol or carefully 2 ...

Page 5: ...TY INFORMATION 4 2 DESCRIPTION 8 3 CONTROL FUNCTION 10 4 PREPARATION 15 5 OPERATION 18 SAFETY WARNINGS 2 CONTENTS 3 7 STORAGE 32 8 TROUBLESHOOTING 34 9 SPECIFICATIONS 35 10 WIRING DIAGRAM 36 6 MAINTENANCE 25 ...

Page 6: ...perating your generator It will help you avoid accidents if you get familiar with your generator s safe operation procedures 1 SAFETY INFORMATION Never use it indoors Never use it in a wet condition Never directly connect it to a home power system 4 ...

Page 7: ...Keep it at least 1m away from inflammables Never smoke when fueling Don t spill when fueling Stop the engine before fueling 5 ...

Page 8: ...rofessional electrician or by another person with proficient electrical skill When the loads are connected to the generator please carefully check whether electrical connections are safe and reliable Any improper connection may cause damage to the generator or cause a fire Connections to a Home Power Supply 6 ...

Page 9: ...y insulated conductor Make sure the control panel louver and the inverter bottom side cooling well and without chips mud and water come in it may damage the engine inverter or alternator if the cooling vent blocked Do not mix the generator with other stuff If moving storing or running the unit It may cause the generator damage or bring property safety issue when the generator in leakage 7 ...

Page 10: ...2 DISCRIPTION ķ Carrying handle ྚ ྛ Fuel tank cap ྜ Control panel ྜྷ Recoil starter ྞ Oil filler cap ྟ Louver ྠ Muffler Spark plug maintenance cover 8 2 1 Control panel ...

Page 11: ...ྛ ྜ ྜྷ ྞ AC reset ྟ DC receptacle USB AC Breaker ྠ Ground earth terminal ྡ DC protector ESC Engine Smart Control Switch knob AC receptacle Parallel function 9 Electric Recoil Oil warning light Overload indicator light AC pilot light ...

Page 12: ...he engine can be running ྛ Engine switch fuel valve choke CHOKE Ignition circuit is switched on Fuel is switched on Choke is switched off The engine can be start TIP The choke is not required to start a warm engine 10 Electric Recoil 25 50 75 100 110 Oil change indicator Air cleaner maintenance indicator Spark plug maintenance indicator Switch button Fuel level indicator On load indicator Oil aler...

Page 13: ...lasts 1hr Green On load indicator light on green while the inverter is on load Red Oil alert light on while the oil is empty Green Inverter working indicator Red Spark plug maintenance indicator indicate once every 100hrs Every indicating lasts 1hr Full Green all lights on Low fuel level lights turn orange Power lower than 25 750W light A truns green Power lower than 50 1500W light A B truns green...

Page 14: ...trol unit overheats or the AC output voltage rises Then the AC protector will trip stopping power generation in order to protect the generator and any connected electric devices The AC pilot light Green will go off and the overload indicator light Red will stay on but the engine will not stop running When the overload indicator light comes on and power generation stops proceed as follows 1 Turn of...

Page 15: ... turns to OFF automatically when electric device being connected to the generator is operating and current above the rated flows To use this equipment again turn on DC protector by pressing its button to ON ˈ t u p t u o t o n s i t n e r r u c t c e r i D F F O Direct current is output ĀON Reduce the load of the connected electric device below the specified rated output of the generator if the DC...

Page 16: ...OFF when using electric devices that require a large starting current such as a compressor of a submergible pump Ground Earth terminal connects the earth line for prevention of electric shock When the electric device is earthed always the generator must be earthed l a n i m r e t h t r a E d n u o r G 6 3 14 Optional configuration PARALLEL CONNECTIONS The parallel connection function allows two un...

Page 17: ...ed gasoline The use of leaded gasoline will cause severe damage to internal engine parts Remove the fuel tank cap and fill the fuel into the tank up to the red level ķ KHQ WKH IXHO ILOWHU VFUHHQ LV QRW marked the volume of the oil level distance from the lip of the oil tank at the 25 4mm of the oil tank is nominal KHQ WKH IXHO ILOWHU LV PDUNHG WKe volume of the fuel is added to the mark Immediatel...

Page 18: ...he oil service door 3 Screw out the oil plug then screw in sealing plug into the pouring orifice and use the funnel to add the specified amount of oil 4 Screw the oil plug installed oil service door and keep the knob to CLOSE 4 2 Engine oil Recommended engine oil SAE SJ 15W 40 Recommended engine oil grade API Service SE type or higher Engine oil quantity 0 6 L Lubricating oil pipe Oil service door...

Page 19: ... operation checks should be made each time the generator is used 4 3 PRE OPERATION CHECK Pre operation check Fuel See page 15 Ь Check fuel level in fuel tank Ь Refuel if necessary Engine oil See page 16 Ь Check oil level in engine Ь If necessary add recommended oil to specified level Ь Check generator for oil leakage The point where abnormality was recognized by use Ь Check operation Ь If necessar...

Page 20: ... result in overfilling and damage to the engine TIP The generator can be used with the rated output load at standard atmospheric conditions Standard atmospheric conditions Ambient temperature 25 Barometric pressure 100kPa Relative humidity 30 The output of the generator varies due to change temperature altitude lower air pressure at higher altitude and humidity The output of the generator is reduc...

Page 21: ...shown in the figure d TIP warm engine Push the choke knob in to the position ON The choke is not required to start a Press the electric start switch as shown TIP warm engine Push the choke knob in to the position ON in the figure The choke is not required to start a 4 Pull slowly on the recoil starter until it is engaged then pull it briskly TIP Grasp the carrying handle firmly to prevent the gene...

Page 22: ...V DUH in good condition before connection to the generator H VXUH WKH WRWDO ORDG LV ZLWKLQ JHQHUDWRU UDWHG RXWSXW H VXUH WKH UHFHSWDFOH ORDG FXUUHQW LV ZLWKLQ UHFHSWDFOH UDWHG FXUUHQW TIP Make sure to ground Earth the generator When the electric device is earthed always the generator must be earthed 1 Turn the ESC to OFF 2 Disconnect any electric devices 3 Turn the switch knob to OFF a Ignition ci...

Page 23: ...y terminal 3 Connect the black battery charger lead to the negative battery terminal 4 Turn the ESC off to start battery charging Ь Be sure the ESC is turned off while charging the battery Ь Be sure to connect the red battery charger lead to the positive battery terminal and connect the black lead to the negative battery terminal Do not reverse these positions Ь Connect the battery charger leads t...

Page 24: ...revent overcharging the battery Never smoke or make and break connections at the battery while charging Sparks may ignite the battery gas Battery electrolyte is poisonous and dangerous causing severe burns etc contains sulfuric sulphuric acid Avoid contact with skin eyes or clothing Antidote EXTERNAL Flush with water INTERNAL Drink large quantities of water or milk Follow with milk of magnesia bea...

Page 25: ...2 400W İ1020W 0U4T0U75 Efficiency 0 85 AC TIP Ь Ь should not exceed the rated output EX Application wattage indicates when each device is used by itself The simultaneous usage of AC and DC power is possible but total wattage Generator rated output Frequency AC DC Power factor 3 000W İ3 000W 100W 12V 8 3A 1U0 Ь application range The overload indicator light comes on when total wattage exceeds the 2...

Page 26: ...se form the engine does not interfere with any other electrical devices located near the generator Ь If the generator is to supply medical equipment advice should first be obtained from the manufacturer a medical professional or hospital Ь Some electrical appliances or general purpose electric motors have High starting currents and cannot therefore be used even if they lie within the supply ranges...

Page 27: ...ools and is proficient with mechanical maintenance Engine oil Reduction gear oil if equipped Air filter element Deposit Cup if equipped Spark Plug Spark arrester Idling if equipped Valve clearan ce Fuel tank fuel filter Fuel line Cylinder head piston Check Refill Replace Oil level check Replace Check Clean Replace Replace Clean Check adjust Clean Check adjust Check adjust Clean Check Clean up carb...

Page 28: ...ssed the scheduled time to maintain your engine do it as soon as possible If the gasoline engine frequently works under high temperature or heavy Stop the engine before servicing Put the engine on a level surface and remove the spark plug cap to prevent the engine from starting Do not operate the engine in a poorly ventilated room or other enclosed area Be sure to keep good ventilation in working ...

Page 29: ...ver 27 6 1 Spark plug inspection The spark plug is important engine components which should be checked periodically Standard Spark Plug F6RTC Spark Plug Gap 0 7 0 8mm TIP The spark plug gap should be measured with a wire thickness gauge and If necessary adjusted to specification Spark Plug Torque 28 N m 5 Install the spark plug TIP If a torque wrench is not available when installing a spark plug a...

Page 30: ...with care to avoid burns 1 Place the generator on a level surface and warm up the engine for several minutes The stop the engine and turn the 3 in 1 switch knob fuel tank cap air vent knob to OFF 2 Remove the screws and then remove th e cover 3 Remove the oil filler cap 4 Place an oil pan under the engine Tilt the generator to drain the oil completely 5 Replace the generator on a level surface Do ...

Page 31: ...ment and squeeze out excess oil The foam element should be wet but not dripping Do not wring out the foam element when squeezing it This could cause it to tear 6 Insert the foam element into the air filter case TIP Be sure the foam element sealing surface matcher is no air leak Foam element Foam element the air filter so there The engine should never run without the foam element excessive piston a...

Page 32: ...ve the screws ྙSG 2 Remove the muffler cap the muffler screen and spark arrester 3 Clean the carbon deposits on the muffler screen and spark arrester using a wire brush 4 Check the muffler screen and spark arrester Replace them if damaged 5 Install the spark arrester TIP Align the spark arrester projection with the hole in the muffler pipe GG When cleaning use the wire brush lightly to avoid damag...

Page 33: ...lter and install it 4 Install the fuel tank cap Be sure the fuel tank cap is tightened securely 6 7 Fuel filter 1 Remove the screws ྙSGand then remove the cover ྚSGand drain the fuelྛG 2 Hold and move up the clamp ྜSGthen take off the hose ྜྷGfrom the tank ྚ 1 3 Take out the fuel filter 4 Clean the filter with gasoline 5 Dry the filter and put it bank into tank 6 Install the hose and clamp then ope...

Page 34: ... stops The engine stops in approx 20 minutes Time by running out of fuel 32 E G A R O T S 7 Long term storage of your machine will require some preventive procedures to guard against deterioration l e u f e h t n i a r D 1 7 1 Turn the switch knob to OFF U 2 Remove the fuel tank cap remove the filter Extract the fuel from the fuel tank into an approved gasoline container Then install the fuel tank...

Page 35: ...r several times with 3 in 1 switch knob off to coat the cylinder walls with oil 2 Pull the recoil starter until you feel compression Then stop pulling This prevents the cylinder and valves from rusting 3 Clean exterior of the generator Store the generator in a dry well wentilated place with the cover placed over it 8 Install the cover and tighten the screws 9 Turn the fuel tank cap air vent knob t...

Page 36: ...e oil system Insufficient Oil level is low Add engine oil Oil level cap Oil level lower limit 3 Electrical systems Put the 1 in 3 switch to CHOKE and pull the recoil starter Poor spark Spark plug dirty with carbon or wet Remove carbon or wipe spark plug dry Faulty ignition system consult our company authorized dealer 8 2 Generator won t produce power Safety device DC protector to OFF Press the DC ...

Page 37: ...enerator set 3kW Silent Inverter 220 230 120 240 2 8 1 ISO8528 G2 12 8 3 Non fuse Protector Engine R210 i Oil Capacity L Spark Model No Starting mode Length Width Height mm Net weight kg 0 6 F6RTC Recoil Electric 643 480 498 42 46 Single cylinder 4 Stroke forced air cooling OHV Engine type Unleaded Gasoline 10 Displacement cc Fuel type Fuel tank capacity L 9 SPECIFICATIONS 212 50 60 3 0 ...

Page 38: ......

Page 39: ......

Page 40: ...93004 YBR0110 0000 ...