8
0
no time interval
1
30 seconds
2
1 minute
3
1 minute, 30 seconds
4
2 minutes
5
2 minutes, 30 seconds
6
3 minutes
7
3 minutes, 30 seconds
8
4 minutes
9
4 minutes, 30 seconds
A signal tone arises to confirm the time interval.
Empty the Safe
Open the Safe as indicated below. The internal part can be subsequently removed.
Close the Safe
Close the door and rotate the handle anticlockwise.
Change of batteries
If the Safe does not want to open, the batteries could be dead. You will hear either a low signal or
no signal at all. The POS Safe requires eight 1,5 Volt batteries (LR6 type, 15 x 50 mm). In order to
open the battery compartment, remove both screws located in the control panel. Exchange the
batteries and make sure that no cable is loose or jammed. In case the Safe does not open
despite the exchange of batteries, please contact the Producer/Sales Representative.