background image

4 |  Installation

en-US

80.51.389_iCombiPro-iCombiClassic_IFA-TG_IM_US-nord

5 / 16

7

Drain valve bracket

8

Drain pipe

9

Connection pipe

10

Double socket

11

Silicon seal double socket

12

Pipe holder rear wall

13

Silicon seal HT pipe

14

Bracket for drain valve

15

Copper seal

16

Drip pan with pipe

17

Plug for cooking cabinet, with fixing
and chain

18

Screw connection with funnel open-
ing

19

Drain fitting

4

Installation

4.1 Preparing the stand

Stand with rear wall:

Break out the perforation for the plate on
the rear wall of the stand [

   Figure 02

].

Stand without rear wall [

   Figure 03

]:

1. Hook the retaining plate on the rear

side of the stand on the table edge.

2. Tighten the 2 screws on the retaining

plate.

4.2 Installing the integrated fat drain

Mounting the drain valve and drain pipes

1. Seal the threads of the two pipe pieces

for the drain valve with teflon tape
[

   Figure 04

].

2. Mount the two parts of the holder on

the drain valve with the tube angle and
the connecting pipe [

   Figure 05

].

3. Turn the tube angle so that it is

mounted at a 90° angle to the holder.

4. Mount the pipe seal on the pipe socket

in the rear wall of the device
[

   Figure 06

].

5. Join the pipes on the rear wall of the

device [

   Figure 07

].

6. Guide the piping into the stand

[

   Figure 08

].

7. Push the drain valve into the top rail of

the stand [

   Figure 09

].

8. Push the piping into the pipe sleeve of

the drain valve [

   Figure 10

].

9. Tighten the clamp screws on the drain

valve holder [

   Figure 11

].

10. Place the front fat collection canister in

front of the stand and the rear fat col-
lection canister in the stand
[

   Figure 12

]. The rear canister must

be positioned in the stand so that the
front fat collection canister can be
placed in front of it after further pre-
liminary work.

11. Insert the drain pipe in the front fat

collection canister and in the tube an-
gle [

   Figure 13

].

12. Turn the drain pipe so that the pin

locks in the tube angle [

   Figure 14

].

13. Push the fat collection tray into the

bottom slot of the device
[

   Figure 15

].

14. Guide the piping in the cooking cabi-

net into the fat collection tray
[

   Figure 16

]. Fix the plugs on the

funnel in the cooking cabinet.

Opening/closing the funnel

1. Leave the funnel in the cooking cabinet

open when using the integrated fat
drain.

>>

The integrated fat drain is mounted on
the device.

Summary of Contents for iCombi Pro 6 half size

Page 1: ...iCP iCC 61 102 US nord Integrated fat drain Original Installationsanleitung Original Installation Manual...

Page 2: ...2 16 80 51 389_iCombiPro iCombiClassic_IFA TG_IM_US nord en US 3 fr ca 6...

Page 3: ...iCombiPro iCombiClassic_IFA TG_IM_US nord 3 16 Table of contents 1 Information on this manual 4 2 Safety 4 3 Product description 4 4 Installation 5 4 1 Preparing the stand 5 4 2 Installing the integra...

Page 4: ...ns from hot drain pipes The pipes of the fat drain can become extremely hot while the unit is in operation n Do not touch the drain pipes during operation n If you are not using the integrated fat dra...

Page 5: ...90 angle to the holder 4 Mount the pipe seal on the pipe socket in the rear wall of the device Figure 06 5 Join the pipes on the rear wall of the device Figure 07 6 Guide the piping into the stand Fi...

Page 6: ...CombiClassic_IFA TG_IM_US nord Table des mati res 1 Informations sur ce manuel 7 2 S curit 7 3 Description du produit 8 4 Installation 8 4 1 Pr parer la table de soubassement 8 4 2 Monter le syst me d...

Page 7: ...du kit Toutes les informations contenues dans le manuel d installation pour iCombi Pro iCombi Classic s appliquent mutatis mutandis 2 S curit AVERTISSEMENT Risque de br lures d aux tuyaux d coulement...

Page 8: ...T 14 Coude pour robinet boisseau sph rique 15 Joint en cuivre 16 Bac collecteur avec tuyau 17 Bouchon de fermeture pour l enceinte de cuisson avec fixation et cha ne 18 Presse toupe avec ouverture en...

Page 9: ...de soubassement Image 12 Le bidon collecteur de graisse arri re doit tre positionn de mani re permettre la mise en place du bidon avant apr s d autres op rations de pr paration 11 Ins rez le tuyau d c...

Page 10: ...10 16 80 51 389_iCombiPro iCombiClassic_IFA TG_IM_US nord...

Page 11: ...80 51 389_iCombiPro iCombiClassic_IFA TG_IM_US nord 11 16 6 7 8 10 5 1 3 13 15 19 12 2 14 17 16 4 11 9 18...

Page 12: ...12 16 80 51 389_iCombiPro iCombiClassic_IFA TG_IM_US nord 1 2...