Service messages
80 / 85
fault indication
when and how
remedial action
service message persists, notify Customer
Service.
E30
Displayed
continuously
Humidity control not working. The unit can
be used for cooking with limitations. - Notify
Customer Service!
E31
When it has been
switched on for 30
seconds,
Core temperature probe is defective. The
unit can be used for cooking without the
core temperature probe. - Notify Customer
Service!
E32
Displayed
continuously.
Close the gas valve. - Notify Customer
Service
E33
This is displayed
continuously after
being reset 4 times.
Close the gas valve. - Notify Customer
Service
E34
Displayed
continuously
Notify Customer Service!
E35
When it has been
switched on for 30
seconds,
Please connect Ultravent® condensation
hood.
E36
When the fault
occurs.
Cooking only possible with some restrictions.
- Notify Customer Service!
E37
When the fault
occurs.
Cooking only possible with some restrictions.
- Notify Customer Service!
E38
When the fault
occurs.
Selection button for cooking mode faulty. -
Notify Customer Service!
E39
When the fault
occurs.
Selection button for cooking cabinet
temperature faulty. - Notify Customer
Service!
E40
When the fault
occurs.
Selection button for cooking time/core
temperature faulty. - Notify Customer
Service!
Summary of Contents for CombiMaster Plus 201
Page 1: ...Original operating instructions CombiMaster Plus...
Page 83: ...EU Declaration of Conformity for electrical appliances 83 85...
Page 84: ...EU Declaration of Conformity for gas appliances 84 85...
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ...80 05 001 V 05 MDS Ad 02 16...