Items Needed
Pre-Installation Steps
Included
• Command Center phone with phone line cable
• Distribution Module
• System wiring (pigtail cables, power cord, ethernet
cable for programming the Distribution Module if
needed)
• Cabinet (wall mount) or Stand (desk mount)
Step 1
Mount the Distribution Module and Power Supply with the battery back up in an appropriate location,
installing the Command Center for wall mount units or the stand for desk mount units accordingly, then
remove the knock outs (if applicable). The recommended location to mount the Distribution Module and
Power Supply is in a network closet or machine room. Mount the Command Center according to the owner’s
specifications.
Follow the diagram below for attaching the extender and foot stand to the back of the Command Center
phone as needed.
Page 3
Not Included
• 22 or 24 AWG twisted, shielded cable
• Multimeter
• Analog phone for troubleshooting
• Recommended: Biscuit jack for each phone (if
needed, not applicable for elevator systems)
Step 2
For 5-16 line systems, remove the screws on the back of the Distribution Module and remove the cover to
expose the internal RJ45 interface connections.