![Rath Janus SmartView Visual Installation & Operation Manual Download Page 7](http://html1.mh-extra.com/html/rath/janus-smartview-visual/janus-smartview-visual_installation-and-operation-manual_3769400007.webp)
LAN Setup
To ensure operation if the external internet is compromised, verify the Head-End and Controllers wire back to the
same network switch or series of network switches. See wiring example below.
Machine Room
Network Switch
Elevator 6
Elevator 3
Elevator 4
Elevator 2
Elevator 1
Head End
Network Switch
Building
Router
Floor 1
Floor 2
Floor 3
Floor 4
Page 7
Appendix A
SmartView Controller Specifications:
•
Power Requirements:
12v or 24v or PoE or PoE+
•
Curent Draw:
12v Active = 1A
12v Idle = 0.5A
24v Active = 0.5A
24v Idle = 0.25A
•
Operating Temperature:
32°F to 158°F (0°C to 70°C)
•
Dimensions:
4” H x 7” W x 1.2” D
SmartView Camera Specifications (Powered by Controller):
•
Power Requirements:
Active = 5v, 0.12A
Idle = 0v, 0A
•
Operating Temperature:
32°F to 140°F (0°C to 60°C)
SmartView Display Specifications (Powered by Controller):
•
Power Requirements:
Active = 5v, 0.59A
Idle = 0v, 0A
•
Operating Temperature:
-4°F to 158°F (-20°C to 70°C)
•
Screen Size:
5 inches
• Part Numbers:
2100-SVD
(0.0625” window)
2100-SVDA
(0.125” window)
2100-SVDB
(0.109” window)
2100-SVDC
(0.078” window)
2100-SVDE
(0.118” window)