Page 3
• RATH® 2100 Series Analog Phone
• Static IP address for IP Interface
• IP address of SIP Server
Note: Address for IP Interface must be on the same network as SIP Server
• Name, authentication password, and authentication ID for SIP extension
• PC with Network Interface Card attached to same network as SIP server
• Battery backed up 120vac power source (RATH® RP7700100)
• Standard analog telephone
1
. Supply power to the IP Interface using battery backed up 120vac power source (RATH® RP7700100)
2
. Connect Ethernet port of IP Interface to network using supplied Ethernet cable
3
. Turn off wireless card on computer (if applicable)
4
. Log into IP Interface
a. Enter IP Interface IP address (192.168.1.160) into web browser (Google Chrome or Mozilla Firefox preferred)
b. Log into Interface
LOGIN:
admin
PASSWORD:
admin
5.
Under
QUICK SETUP
Enter SIP Server information in IP Interface
a. Enter IP address of SIP server in PROXY box
b. Enter name as it will appear on phone in DISPLAY NAME
c. Enter Authentication ID in USER ID
d. Enter Authenitication Password in PASSWORD
e. Click
SUBMIT
at the bottom of the page (the unit will automatically reboot)
6
. Log back into unit and Change IP address settings of IP Interface
a. Click
NETWORK SETUP
under the menu options on the top of the screen
b. Enter desired IP address, subnet mask, and default router for IP Interface
c. Click
SUBMIT
at the bottom of the page (the unit will automatically reboot)
Items Needed
IP Interface Set-Up for Static IP
Testing the IP Interface
1.
After configuration, place a test call from analog phone connected to phone port
2.
If test call is successful, IP Interface is ready for operation
3.
A RATH® 2100 Series analog Phone can be plugged in at this time