background image

     POE                        LAN

INPUT

 

100-240Vac

 SELECTOR

 15V  24V

12V SOLAR

INPUT

 SELECTOR OUTPUT

12V OUTPUT 

 9V

12V

{

}

1

2

Phone

WIFI

IPAD

PSP

Thank you for choosing the OMNIPOWER RATEL MICRO UPS. 

Before operating this unit, please read the USER MANUAL 

carefully to ensure the best possible performance is obtained. 

1)   OmniPower Ratel 860P
2)   AC power cable
3)   DC output cables (2 ends)
4)   User's manual
5)   Warranty card

1 .  OMNIPOWER RATEL MICRO UPS package

1)   ON/OFF Switch
2)   Work status indicator 
3)   12Vdc LED Indicator
4)   9Vdc LED Indicator
5)   25

BAT

 

capacity

 

LED

 

Indicator

6)   50

BAT

 

capacity

 

LED

 

Indicator

7)   75

BAT

 

capacity

 

LED

 

Indicator

8)   100

BAT

 

capacity

 

LED

 

Indicator

9)   Ethernet output interface
       (POE output: 15V/24V)
 

 
10)   LAN   Ethernet interface LAN
11)  Output Voltage Selector(15V/24V)
12)   12Vdc solar input
13)   Output Voltage Selector(9V/12V)
14)   Output socket(9V/12V) 5mm
15)   Output socket
16)   AC input socket 
17)   Output socket 5V 
18)   USB (5Vdc) output

2 .  Instructions of the components

3 .   Features

4 .   High compatibilities

2

3

4

5

7

8

6

1

9

10

11

12

13

14

15

16

Ratel 860P

5Vdc OUTPUT

USB

USB

17

18

Rated working voltage

Output power(Max.)

Output

Output voltage(selectable)
Output polarity

Output power & current (in common)

QTY. & capacity of battery

Unit dimension(mm)

Net weight(kg)

    100~240Vac/50-60Hz

                    60W

3

4

USB interface

DC interface

5Vdc

9 / 12Vdc

2.0A / 10W

2200mAh*8

5 .   How to use

Products specifications are subject to change without notice.

6 .   Specifications

M

odel

Ratel 860P

5Vdc

Solar input

 polarity

12

~

25Vdc  |  Up to 50W

Solar input 

voltage range

252*146*45

0.94

standard

12VdcX4

5.0A/60W

2.0A/24W

POE interface

15Vdc / 24Vdc

+

4,5pins -7,8pins

1.0A/(15.8V16W)

or

(

24V24W) 

RATEL

MICRO UPS with Li-Ion Battery

 5mm socket

V2 16072020

1.  High-capacity lithium batteries provide long backup to your loads.
2.  High compatibility, the Ratel is suitable for most digital products on the 

market.

3.  USB output (5V) can supply charge for devices such as mobile phone, PSP, 

IPod, MP4, etc.

4.  Power Over Ethernet (POE) can transmit data and power simultaneously, 

thus simplifiying the wiring.

5.  Intelligent circuit design with over-charge, over-discharge and short-

circuit protection.

6.  Built-in adapter allows wide AC voltage range (85 ~ 265Vac)
7.  Built-in solar charger

1.  High-capacity lithium batteries provide long backup to your loads.
2.  High compatibility, the Ratel is suitable for most digital products on the 

market.

3.  USB output (5V) can supply charge for devices such as mobile phone, PSP, 

IPod, MP4, etc.

4.  Power Over Ethernet (POE) can transmit data and power simultaneously, 

thus simplifiying the wiring.

5.  Intelligent circuit design with over-charge, over-discharge and short-

circuit protection.

6.  Built-in adapter allows wide AC voltage range (85 ~ 265Vac)
7.  Built-in solar charger

1.  In order to prevent over-discharge of the lithium batteries, please restart the 

Ratel when AC power becomes available after low-battery cutoff.

2.  Before connecting loads to the Ratel, it is essential that you check their nominal 

working voltage, current and polarity, which you will find on their original 
adapters.

3.  The output power of this model is controlled by total power capacity. The total 

power of the loads which connect to all the ports cannot exceed the maximum 
output power of your model. If this does occur, the USB ports will be closed and 
the status light will flash yellow. If the total power of the loads still exceeds the 
maximum power rating after the USB ports are closed, all the output ports will 
be closed, and all power indicator lights will flash. In this situation, please 
remove excess loads.

4.  Press and hold the power key for 2 to 3 seconds to boot up the Ratel. If the 

output voltage indicator is green, this DC port is outputting voltage, and one 
can select between 9V and 12V by sliding the DC voltage switch. After plugging 
the Ratel into the grid, the status light will turn green to indicate the battery is 
charging. 100% means the battery is fully charged. In the process of charging, 
the power indicator light indicates the capacity of the battery in 25% increments 
– 25%, 50%, 75% and 100%. When disconnected from the grid, the power 
indicator lights will indicate the decreasing capacity of the battery in 25% 
increments – 100%, 75%, 50% and 25%. When the indicator light at the 25% 
marks begins to flash, this means that battery power is very low. Press and hold 
the power key for 2 to 3 seconds to turn off the Ratel and stop output voltage.

5.  The plug-and-play USB provides stable charging to digital products with their 

original cables.

6.  The Ratel will shut down automatically when it reaches low battery status; it will 

restart with output power when the AC power is restored.

7.  If the Ratel will not be used for extended periods, ensure that it is fully charged 

before storing in a cool, dry place. If the Ratel has been in storage too long, you 
will need to plug in grid power until the status light turns green. It is 
recommended that the Ratel battery is charged once per month.

8.  The built-in solar module has constant current and voltage control; it can charge 

lithium batteries on startup or in shutdown state when connected to a solar 
panel, and will supply power to your loads when your UPS is on.

1.  In order to prevent over-discharge of the lithium batteries, please restart the 

Ratel when AC power becomes available after low-battery cutoff.

2.  Before connecting loads to the Ratel, it is essential that you check their nominal 

working voltage, current and polarity, which you will find on their original 
adapters.

3.  The output power of this model is controlled by total power capacity. The total 

power of the loads which connect to all the ports cannot exceed the maximum 
output power of your model. If this does occur, the USB ports will be closed and 
the status light will flash yellow. If the total power of the loads still exceeds the 
maximum power rating after the USB ports are closed, all the output ports will 
be closed, and all power indicator lights will flash. In this situation, please 
remove excess loads.

4.  Press and hold the power key for 2 to 3 seconds to boot up the Ratel. If the 

output voltage indicator is green, this DC port is outputting voltage, and one 
can select between 9V and 12V by sliding the DC voltage switch. After plugging 
the Ratel into the grid, the status light will turn green to indicate the battery is 
charging. 100% means the battery is fully charged. In the process of charging, 
the power indicator light indicates the capacity of the battery in 25% increments 
– 25%, 50%, 75% and 100%. When disconnected from the grid, the power 
indicator lights will indicate the decreasing capacity of the battery in 25% 
increments – 100%, 75%, 50% and 25%. When the indicator light at the 25% 
marks begins to flash, this means that battery power is very low. Press and hold 
the power key for 2 to 3 seconds to turn off the Ratel and stop output voltage.

5.  The plug-and-play USB provides stable charging to digital products with their 

original cables.

6.  The Ratel will shut down automatically when it reaches low battery status; it will 

restart with output power when the AC power is restored.

7.  If the Ratel will not be used for extended periods, ensure that it is fully charged 

before storing in a cool, dry place. If the Ratel has been in storage too long, you 
will need to plug in grid power until the status light turns green. It is 
recommended that the Ratel battery is charged once per month.

8.  The built-in solar module has constant current and voltage control; it can charge 

lithium batteries on startup or in shutdown state when connected to a solar 
panel, and will supply power to your loads when your UPS is on.

WARNING:

1.  Always check the working voltage, current and polarity of the 

loads before connecting them to the Ratel, then choose the 
corresponding voltage.

2.  Charge device fully prior to initial use.
3.  Damage caused by dropping, disassembling or attempting to 

repair the Ratel privately will render your warranty null and 
void.

4.  Do not immerse the Ratel in water or allow it to get wet.
5.  Do not dispose of any of the Ratel's components in fire.
6.  Do not use the Ratel in flammable environments
7.  Keep the Ratel out of reach of children and unauthorised 

persons.

1.  Always check the working voltage, current and polarity of the 

loads before connecting them to the Ratel, then choose the 
corresponding voltage.

2.  Charge device fully prior to initial use.
3.  Damage caused by dropping, disassembling or attempting to 

repair the Ratel privately will render your warranty null and 
void.

4.  Do not immerse the Ratel in water or allow it to get wet.
5.  Do not dispose of any of the Ratel's components in fire.
6.  Do not use the Ratel in flammable environments
7.  Keep the Ratel out of reach of children and unauthorised 

persons.

Please do not disassemble, squeeze or short 
circuit the batteries. Do not dispose of the 
batteries by means of fire or water. Do not place 
the Ratel in environments where temperature 
exceeds 60

°

C (140

°

F)

Please do not disassemble, squeeze or short 
circuit the batteries. Do not dispose of the 
batteries by means of fire or water. Do not place 
the Ratel in environments where temperature 
exceeds 60

°

C (140

°

F)

Tel: +27 11 453 0924   I  www.probegroup.co.za

Summary of Contents for 860P

Page 1: ...possible performance is obtained Ratel 860P RA TEL MICRO UPS with Li Ion Battery Thank you for choosing the OMNIPOWER RATEL MICRO UPS Before operating this unit please read the USER MANUAL carefully to ensure the best possible performance is obtained Ratel 860P RA TEL MICRO UPS with Li Ion Battery Tel 27 11 453 0924 I www probegroup co za ...

Page 2: ...city LED Indicator 6 50 BAT capacity LED Indicator 7 75 BAT capacity LED Indicator 8 100 BAT capacity LED Indicator 9 Ethernet output interface POE output 15V 24V 10 LAN Ethernet interface LAN 11 Output Voltage Selector 15V 24V 12 12Vdc solar input 13 Output Voltage Selector 9V 12V 14 Output socket 9V 12V 5mm 15 Output socket 16 AC input socket 17 Output socket 5V 18 USB 5Vdc output 2 Instructions...

Page 3: ...arket 3 USB output 5V can supply charge for devices such as mobile phone PSP IPod MP4 etc 4 Power Over Ethernet POE can transmit data and power simultaneously thus simplifiying the wiring 5 Intelligent circuit design with over charge over discharge and short circuit protection 6 Built in adapter allows wide AC voltage range 85 265Vac 7 Built in solar charger Tel 27 11 453 0924 I www probegroup co ...

Page 4: ... the battery is charging 100 means the battery is fully charged In the process of charging the power indicator light indicates the capacity of the battery in 25 increments 25 50 75 and 100 When disconnected from the grid the power indicator lights will indicate the decreasing capacity of the battery in 25 increments 100 75 50 and 25 When the indicator light at the 25 marks begins to flash this mea...

Page 5: ...W POE interface 15Vdc 24Vdc 4 5pins 7 8pins 1 0A 15 8V16W or 24V24W 5mm socket WARNING 1 Always check the working voltage current and polarity of the loads before connecting them to the Ratel then choose the corresponding voltage 2 Charge device fully prior to initial use 3 Damage caused by dropping disassembling or attempting to repair the Ratel privately will render your warranty null and void 4...

Page 6: ...ssemble squeeze or short circuit the batteries Do not dispose of the batteries by means of fire or water Do not place the Ratel in environments where temperature exceeds 60 C 140 F Tel 27 11 453 0924 www probegroup co za ...

Reviews: