23. Cashless REVALUE
<HEADER>
<CMD>
<SUBCMD>
<PARAMETERS>
<CRC>
0xFE
0x53
0x08
<CASHLESS NUMBER> (0x01 = cashless #1, 0x02 =
cashless #2)
CRC
RASPIVEND answer
0xFE
0x53
0x08
0xFB – command execution failed
0xFC – command successfully executed
0xFD – command CRC error
CRC
This command will transform the remaining cash credit into cashless credit and will refund
this amount on customer's account.
24. Cashless READ VECTORS
<HEADER>
<CMD>
<SUBCMD>
<PARAMETERS>
<CRC>
0xFE
0x53
0x09
<CASHLESS NUMBER> (0x01 = cashless #1, 0x02 =
cashless #2)
CRC
RASPIVEND answer
0xFE
0x53
0x09
<CASHLESS SETUP> - 8 bytes
<CASHLES EXPANSION INFORMATION> - 30 bytes
CRC
This command will return the low level settings of the cashless device, according to MDB
protocol.
25. Cashless END SESSION
<HEADER>
<CMD>
<SUBCMD>
<PARAMETERS>
<CRC>
0xFE
0x53
0x0A
<CASHLESS NUMBER> (0x01 = cashless #1, 0x02 =
cashless #2)
CRC
RASPIVEND answer
0xFE
0x53
0x0A
0xFB – command execution failed
0xFC – command successfully executed
0xFD – command CRC error
CRC
This command will return turn the session off and will force the cashless device to return to
idle state.
© 2016 – AUTOMATROM SRL – www.vendingtools.ro