10. RESIDUAL RISKS
Even though the cutting unit is safe, operators must pay attention to preserve their and other
people’s safety.
L
At the end of the working operations, the metal parts could be very hot.
L
The cutting blade can work even when the protective device is disassembled.
WARNING
The operator must arrange a disconnetting switch on the supply line in order to switch off the
machine, if necessary.
To connect the new cable open the cover “
A
” by unscrewing the
4 cross-slotted screws “
B
” (see picture 3). Connect the phase
cable to the terminal board. The minimum section of the
connecting cables must be determined by the operator in charge
of the installation.
We recommend using safety cables and sockets IMQ approved.
Check the connection by enabling the cutting unit and verify
the rotation direction. The cutting unit is provided with earthing
(yellow-green cable). Possible faulty earthing connections may
cause unsafe working conditions. Possible damages are not at
RASOR
®
s.r.l. charge.
The electric feeding must be supplied by a line protected against
overcurrent by means of the automatic switch (magnetothermal) or delayed fuses with a
suitable dimensions. The current of the safety devices must be as low as possible considering
the max. absorption of the machine (see identification plate).