background image

15

English

How to use

To set the timer

2 sets of ON and OFF timers are available to turn 
ON or OFF the unit at different preset times.

ON

OFF

SET

CANCEL

1

2

3

TIMER

CANCEL

3

TIMER

1

2

3

1

Select ON or OFF timer

Example: 
OFF at 22:00

• Each time pressed:

OFF

Cancel

2

Set the time

2

3

Confi rm

SET

TIMER

• To cancel ON or OFF timer, press 

ON

 or 

OFF

 to 

select respective   or   then press 

CANCEL

.

• If timer is cancelled manually or due to power 

failure, you can restore the timer again by 
pressing 

ON

 or 

OFF

 to select respective   or 

 then press 

SET

.

• The nearest timer setting will be displayed and 

will activate in sequence.

• When ON Timer is set, the unit may start earlier 

(up to 30 minutes) before the actual set time 
in order to achieve the desired temperature on 
time.

• Timer operation is based on the clock set in the 

remote control and repeats daily once set. For 
clock setting, please refer to Quick guide.

Note

POWERFUL/

QUIET

 , 

nanoe-G

 , 

SLEEP

• Can be activated in all modes and can be 

cancelled by pressing the respective button 
again.

POWERFUL/

QUIET

• Cannot be selected at the same time.

POWERFUL/

QUIET

To switch between powerful & 
quiet

QUIET

POWERFUL

NORMAL

POWERFUL: To reach temperature quickly

POWERFUL/QUIET

• This operation stops automatically after 15 minutes.

QUIET: To enjoy quiet operation

POWERFUL/QUIET

• This operation reduces air

fl

 ow noise.

FAN SPEED

To select fan speed

(Remote control display)

AUTO

FAN

• For AUTO, the indoor fan speed is automatically 

adjusted according to the operation mode.

AIR SWING

To adjust vertical airfl ow 
direction

(Remote control display)

• Keeps the room ventilated.

• In COOL/DRY mode, if AUTO is set, the 

fl

 ap swings 

up/down automatically.

• In HEAT mode, if AUTO is set, the horizontal 

fl

 ap is 

fi

 xed at the predetermined position.

• Do not adjust the 

fl

 ap by hand.

To adjust horizontal airfl ow direction

• Manually adjustable.

Auto Restart Control

• If power is resumed after a power failure, the 

operation will restart automatically after a period 

of time with previous operation mode and air

fl

 ow 

direction.

• This control is not applicable when TIMER is set.

Summary of Contents for RS-LE9SK

Page 1: ...ructions Air Conditioner ACXF55 01450 2 9 18 Rasonic Operating Instructions Air Conditioner 10 18 Thank you for purchasing Rasonic Air Conditioner Installation instructions attached Before operating t...

Page 2: ...2 4 5 6 7 8 9 18 AAA R03 2 2 DBT WBT C DBT WBT DBT WBT COOL 32 23 43 26 16 11 16 11 HEAT 30 24 18 16 5 6 nanoe G...

Page 3: ...IONER OFF ON ON OFF SET CANCEL 1 2 3 TIMER MODE TEMP CLOCK SET CHECK RESET AC RC MODE POWERFUL QUIET AIR SWING FAN SPEED nanoe G SLEEP AIR CONDITIONER ON OFF SET CANCEL 1 2 3 TIMER CLOCK SET CHECK RES...

Page 4: ...4...

Page 5: ...5 ELCB RCD ELCB GB ON COOL DRY Ni Cd...

Page 6: ...NG FAN SPEED nanoe G SLEEP OFF ON ON OFF SET CANCEL 1 2 3 TIMER TEMP CLOCK CHECK 10 C F POWER TIMER nanoe G POWERFUL QUIET OFF ON AUTO COOL HEAT nanoe G nanoe G OFF ON nanoe G AUTO nanoe G POWER nanoe...

Page 7: ...ON OFF 22 00 OFF OFF Cancel 2 2 3 SET TIMER ON OFF CANCEL ON OFF ON OFF SET ON 30 POWERFUL QUIET nanoe G SLEEP POWERFUL QUIET POWERFUL QUIET QUIET POWERFUL NORMAL POWERFUL POWERFUL QUIET 15 QUIET POWE...

Page 8: ...ER TIMER nanoe G POWER FUL QU IET nanoe G H99 pH 7 40 C POWER TIMER nanoe G POWERFU L QUIET 1 2 2 3 POWER TIMER nanoe G POWERFU L QUIET 1 nanoe G 2 2 OFF ON COOL HEAT 15 COOL 8 C HEAT 14 C HEAT 2 3 na...

Page 9: ...9 30 TIMER POWER ON nanoe G HEAT COOL TIMER ON OFF SET CANCEL 1 2 3 TIMER CLOCK SET CHECK RESET AC RC ON OFF SET CANCEL 1 3 TIMER CLOCK SET RESET AC RC 5 2 1 5 3 4 4...

Page 10: ...ioner under the following temperature range DBT Dry bulb temperature WBT Wet bulb temperature Temperature C Indoor Outdoor DBT WBT DBT WBT COOL Max 32 23 43 26 Min 16 11 16 11 HEAT Max 30 24 18 Min 16...

Page 11: ...DE POWERFUL QUIET AIR SWING FAN SPEED nanoe G SLEEP 3 2 1 8m Basic operation 1 Select the desired mode DRY AUTO HEAT COOL 2 Start stop the operation POWER Please note that the indication is on display...

Page 12: ...ric shock or fire Confirm with authorised dealer or specialist on usage of any specified refrigerant type Using refrigerant type other than the specified may cause product damage burst and injury etc...

Page 13: ...ly strong lightning activity CAUTION Indoor unit and outdoor unit Do not wash the indoor unit with water benzine thinner or scouring powder to avoid damage or corrosion at the unit Do not use for pres...

Page 14: ...n may activate only once a day after the unit turned off To remove the moisture left in the internal parts the fan will operate for 30 minutes with flap opened slightly This process only applicable wh...

Page 15: ...an be activated in all modes and can be cancelled by pressing the respective button again POWERFUL QUIET Cannot be selected at the same time POWERFUL QUIET To switch between powerful quiet QUIET POWER...

Page 16: ...T Insert at both sides 1 nanoe G Generator Once every 2 weeks Clean with dry cotton bud Do not touch during operation Air filters Once every 2 weeks Wash rinse the filters gently with water to avoid d...

Page 17: ...aporation occurs on pipes TIMER indicator is always on The timer setting repeats daily once set Indoor fan stops occasionally during heating operation To avoid unintended cooling effect POWER indicato...

Page 18: ...symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symb...

Page 19: ...19 Memo...

Page 20: ...ACXF55 01450 SS0116 0 Printed in Malaysia Panasonic Corporation Website http www panasonic com Panasonic Corporation 2016...