With the 

PILOT THERMOCOUPLE ASSEMBLY

 (Figure 2A) attached to the 

PILOT SUPPORT BRACKET 

(Figure 2B),   

insert the 

10-32 BOLTS 

(Figure 2C) through the pre-drilled holes of the Pilot Support Bracket and into the threaded 

holes of the Pilot Thermocouple Assembly (Figure 2A). Tighten with flathead screwdriver. 

 STEP TWO:   ATTACH PILOT (Figures 2 thru 5) 
 NOTE:  

The following pilot attachment instructions apply to each burner model shown in Figures 2 thru 5. 

FIGURE 2 (F, FX, FA and FAX Burners)  

B) Pilot Support 

     Bracket  

E) 10-32 nut 

C) 10-32 bolts 

F) Burner Pipe  

 

FIGURE 3 

CS/CA Burners  

 

10-32 bolts 

ASSEMBLY 

 

STEP ONE: BURNER PAN FITTINGS (Figure 1) 

 

NOTE: 

If fittings do not come pre-wrapped with Teflon threaded tape, pipe compound must be applied to the non-flared  

            threads. 

 

1. Ensure 

that 

the 

BURNER PLUG 

(Figure 1A.) is inserted into the opposite end of the 

BURNER PIPE 

(Figure 1B)   

      and wrench tightened. 

 

2.  Thread the Natural Gas or Propane Burner Pan Inlet Assembly into the 

BURNER PAN 

(Figure 1C). 

 

• 

Natural Gas Burners (NG) 

(F, FX, CS, CXF, TNA) Insert the 

BURNER ORIFICE 

(Figure 1D) into the 

INTERNALLY 

TAPPED 3/8 FLARED x 3/8 MIP ELBOW 

(Figure 1E) and wrench tighten. (Orifices and Fittings are provided with the 

Burner Pan

)  

 

• 

Propane Burners (LP) 

(FA, FA-X, CA, CXFA, TNA/LP) requires 

MA 

(Figure 1F) or

 MA-2 

(Figure 1G) 

AIR MIXER 

 

      ASSEMBLY.

 Insert the Internally Tapped 3/8 Flared x 3/8 MIP Elbow and wrench tighten. Thread the Air Mixer onto  

      the 3/8 Flared x 3/8 MIP Elbow and wrench tighten with air intake hole positioned horizontally and parallel with the floor. 

A) Burner Plug 

B) Burner Pipe 

C) Burner Pan 

E) Internally Tapped 3/8 Flared x 3/8 

MIP Elbow 

FIGURE 1 

G) Air Mixer For CA Burner Inlet Assembly (MA) 

(Supplied with burner only) 

F) Air Mixer For LP Gas Burner Inlet Assembly (MA2) 

 D) Orifice 

Propane Burner  

Inlet Assembly

 

Natural Gas Burner  

Inlet Assembly

 

A) Pilot Thermocouple Assembly 

Pilot  

Thermocouple  

Assembly 

Summary of Contents for RPK3E

Page 1: ...ASSEMBLY INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE What sets Rasmussen Safety Pilot Kits apart from those of other manufacturers aside from quality is the ease and affordability with which our valve can be upgraded from manual operation to one of several remote control devices WIRELESS REMOTE OPTIONS each sold separately Wireless Wall Thermosta...

Page 2: ... BURNER PIPE Figure 1B and wrench tightened 2 Thread the Natural Gas or Propane Burner Pan Inlet Assembly into the BURNER PAN Figure 1C Natural Gas Burners NG F FX CS CXF TNA Insert the BURNER ORIFICE Figure 1D into the INTERNALLY TAPPED 3 8 FLARED x 3 8 MIP ELBOW Figure 1E and wrench tighten Orifices and Fittings are provided with the Burner Pan Propane Burners LP FA FA X CA CXFA TNA LP requires ...

Page 3: ... OUTPUT 3 8 FLARED FITTING WITH 10 FLEX CONNECTOR ATTACHED VALVE INPUT 3 8 FLARED FITTING Attach to Gas Supply PILOT INPUT FIGURE 6 Connect 10 FLEX CONNECTOR Figure 6A between the flared ends of the VALVE OUTPUT 3 8 FLARED FITTING Figure 6B and the BURNER INPUT 3 8 FLARED 3 8 x MIP ELBOW Figure C Bend the 10 Flex Connector to the optimum Valve position forward and to the side of the Burner pan low...

Page 4: ...e failure and voiding of warranty Replace immediately if removed for any reason The EASY Safety Control Valve must be protected to a maximum ambient temperature of 225 F Excessive heat to the valve is indicated by melted plastic or wiring on the valve body and is not warrantable Allow an adequate period of cooling after use before closing glass doors NEVER operate your gas log set with glass doors...

Page 5: ... Burners Burner Pipe Burner Pan Pilot Thermocouple Assembly Flex Connector Heat Shield Burner Pipe Burner Pan Pilot Thermocouple Assembly Flex Connector Heat Shield Each shown with EASY Safety Valve and Receiver placed as far forward and to the side of the burner pan as possible EASY Safety Valve Remote Receiver EASY Safety Valve RemoteReceiver Pilot Thermocouple Assembly EASY Safety Valve RemoteR...

Page 6: ...less flame counter clockwise for more 4 If after pilot adjustment the burner begins to shutdown re adjust for a longer pilot flame STEP TWO PILOT ADJUSTMENT THERMOCOUPLE ASSEMBLY FIGURE 9 1 2 A PILOT B THERMOCOUPLE TIP NOTE The VALVE KNOB has complete control of gas to the pilot and burner It cannot be turned to OFF without first depressing dial to the PILOT position and then rotating clockwise to...