Rasmussen K18-C1C-M-N Assembly, Installation And Operation Instructions Download Page 11

HOW TO ORDER PARTS

Parts can be ordered through the supplier from whom
you purchased your CHILLBUSTER.
When ordering parts, always specify (From information
available on name plate attached to grate) the following:

1. Model number of the CHILLBUSTER.
2. Serial number of the CHILLBUSTER.
3. Type of gas (natural or propane Gas).
4. The name of the part and part number from parts list.

Save these instructions

Manufactured By:  RASMUSSEN IRON WORKS,  INC. 

12028 E. Philadelphia Street
Whittier, California  90601

CONSUMER RECORD CARD

Fill in blanks below for your permanent record.

DATE PURCHASED                

              

              

              

MODEL NO.

              

              

              

            

DATE INSTALLED

              

              

              

              

S E R I A L   N O .

              

              

              

              

INSTALLED BY:

              

              

              

              

G A S   T Y P E :

              

              

              

              

DEALER:

              

              

              

            

PARTS LIST C1A/C, C1B/D and DFC1/C1C

(Manual, Switch or Remote)

1

6

3

4

5

6

7

9

1 0

2 0

2 1

2 2

2 4

2 6

3 1

3 0

2 3

2 5

2

8

3 2

3 3

4 0

4 1

4 2

4 3

5 0

5 1

6 0

6 1

6 2

1.

O22 Burner (40,000 BTU) or

9.

Push Button Ignitor

DFC1/C1C Double Face

43.

Valve Knob

O38 Burner (23,000 BTU)

10.

Inlet Aluminum Connector

30.

Grate

2.

Pilot Manifold Tubing

C1A/C and C1B/D

31.

Front Logs (2)

MILLIVOLT SWITCH SETS

3.

O.D.S. Assembly (Natural) or

20.

Grate

32.

Top Logs (2) Large

50.

Manual 3 Way Switch and

O.D.S. Assembly (Propane)

21.

Front Log

33.

Top Logs (4) (Small)

Cover

4.

Regulator Inlet Brass Elbow

22.

Rear Log

51.

Millivolt Gas Valve

5.

Burner Manifold Tubing

23.

Top Log Large (Left)

MANUAL CONTROL SETS

6.

Orifice Holder

24.

Top Log Small (Left)

40.

Gas Pressure Regulator (Nat)

MILLIVOLT REMOTE SETS

7.

Orifice (Natural) or

25.

Top Log Small (Right) 24" &

or Pressure Regulator (LP)

60.

Receiver Box and Cover

Orifice (Propane)

30" Only

41.

Combination Gas Valve

61.

Receiver

8.

Regulator Outlet Brass Elbow

26.

Top Log Large (Right)

42.   Valve Knob Extender (30" Only)

62.

Transmitter

11

Summary of Contents for K18-C1C-M-N

Page 1: ...sted ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNIN...

Page 2: ...a CHILLBUSTER is installed 3 The minimum size in inches of the fireplace in which this CHILLBUSTER is to be installed must be as follows SET SIZE MODEL NUMBER FRONT WIDTH HEIGHT DEPTH 18 24 30 18 24...

Page 3: ...USTER is very realistic in appearance it is not a real wood burning fireplace Matches paper garbage or any other material must not be thrown on top of the logs or into the flames Avoid contact with th...

Page 4: ...table Btu Hr 72 000 Btu Hr Actual Btu Hr Used 11 840 Btu Hr Excess Non Supportable Btu Hr In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr the space would be consid...

Page 5: ...bing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless pois...

Page 6: ...OX Figure 3 4 Standard Fireplace Hood with a minimum 4 inch horizontal projection beyond vertical surface ABOVE hood as provided by most major fireplace manufacturers IF YOU CANNOT MEET THESE MINIMUM...

Page 7: ...VIEW FRONT VIEW Front Log Rear Log Top Log Large R Top Log Large L Top Log Small L Top Log Small R Front Log Rear Log Top Log Large R Top Log Small R Top Log Large L Top Log Small L Main burner 24 30...

Page 8: ...Valve Knob until air is bled and gas flows to pilot Press PIEZO IGNITOR Button Figure 9 to light pilot Continue to hold valve knob in until Pilot remains lit when knob is released 5 Slowly turn knob t...

Page 9: ...ared and operate instantly and requires you to aim and hold the transmitter for 1 to 3 seconds to operate Manual Operation Receiver switch position ON or OFF does not require batteries Remote Operatio...

Page 10: ...the area around the CHILLBUSTER free and clear from debris From time to time visually check pilot and burner flames for proper appearance Figures 15 and 16 Normal flame color should be yellow body sur...

Page 11: ...20 21 22 24 26 31 30 23 25 2 8 32 33 40 41 42 43 50 51 60 61 62 1 O22 Burner 40 000 BTU or 9 Push Button Ignitor DFC1 C1C Double Face 43 Valve Knob O38 Burner 23 000 BTU 10 Inlet Aluminum Connector 30...

Page 12: ...as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty c...

Page 13: ...CPW CB 2 96 CHANGES next page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 13...

Reviews: