background image

ATTENTION

READ THESE INSTRUCTIONS
CAREFULLY BEFORE ASSEMBLY

REQUIRED TOOLS AND MATERIALS:

 Screw Driver, Adjustable Wrench, Pipe Wrench,  Pipe

Sealing Compound, Matches.

PREPARATION:

1. This Gas Log set must be INSTALLED IN A FULLY VENTED 

METAL OR MASONRY FIREPLACE WITH A WORKING FLUE 
THAT IS SAFE FOR BURNING A WOOD FIRE. 
The Flue MUST 
BE FREE OF ANY OBSTRUCTIONS.

2. Turn off gas supply to fireplace.

3. Clean fireplace floor of any ashes.

4. Attach damper clamp over edge of fireplace damper blade as shown at 

Figure 1.  When installed properly, damper clamp prevents accidental full 
closure of damper.  If unable to install provided damper clamp, consult 
IMPORTANT INFORMATION on front page of these directions.

Damper Stop
Clamp

Damper

Chimney
Flue

Figure 1

STEP ONE: Burner Pan Assembly.

Attaching Burner Pan Legs (All Applications)

 

B

INSIDE

PAN

C

D

Figure 2

A

1.

Place F I B E R   W A S H E R   ( B )  onto  BOLT (A). Insert  BOLT (A)

with FIBER WASHER (B) through the pre-drilled hole in LEG (C).  

2.

Attach  L E G   ( C )  through pre-drilled hole at outside-bottom corner

of BURNER PAN with  NUT (D).  Wrench tighten  NUT (D)  securely
to ensure mechanical strength and a tight gas seal.  Repeat for all four
legs.  See Figure 2.

N O T E :     In extremely low fireplaces or where andirons are being
used, the  L E G S  may be left off.   H O W E V E R ,   T O   P R E V E N T
G A S   L E A K I N G   B E N E A T H   T H E   B U R N E R   P A N ,   T H E   N U T -
B O L T   A N D   F I B E R   WASHER      

MUST

      BE  INSTALLED  TO

ENSURE GAS TIGHT INTEGRITY.

Standard Match Lighted
• (For use only with Natural Gas Models CS, CS-W)

WARNING: A SAFETY PILOT MUST BE
INSTALLED ON ALL UNITS DESIGNED

OR CONVERTED TO BURN

P R O P A N E / L P   G A S

1.

Apply pipe compound to threaded end of 3/8"

FLARED BRASS ELBOW (A).  Do not apply pipe
compound to flared end.  Thread into BURNER PAN
INLET (B)
 and wrench tighten.  See Figure 3

A

B

Figure 3

Accessory Match Lighted Manual V17B Valve
• (For use only with Natural Gas Models CS, CS-W)

WARNING: A SAFETY PILOT MUST BE

INSTALLED ON ALL UNITS DESIGNED

OR CONVERTED TO BURN

P R O P A N E / L P   G A S

A

B

C

Figure 4

BURNER INLET

Figure 5

A

ON

OFF

.

1. Apply pipe compound to the 3/8" inlet threads of  V - 1 7   V A L V E   ( A )   body.  Thread
brass  C O N N E C T O R   F I T T I N G   ( B ) onto inlet threads of  V - 1 7   V A L V E   ( A )  body and
wrench tighten.  Insert  VALVE HANDLE (C) over V-17 VALVE STEM.  See Figure 4 .

2. Apply pipe compound to the 3/8" outlet threads of V-17 VALVE (A) body.  Thread into
BURNER INLET and wrench tighten.  See Figure 5.

3

f i r e - p a r t s . c o m

Summary of Contents for CS

Page 1: ...ot reach your gas supplier call the fire department IMPORTANT INFORMATION THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED SOLID FUEL BURNING FIREPLACE WITH A WORKING FLUE CONSTRUCTED OF NON COMBUSTIBLE MATERIAL The minimum permanent free opening of the fireplace chimney or chimney damper must be at least 39 square inches based on a minimum chimney height of at least 8 feet The area of the flu...

Page 2: ...rner WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log set may give off carbon monoxide an odorless colorless poisonous gas Some people pregnant women persons with heart or lung disease anemia or under the influence of alcohol and persons at high altitudes are more affected by carbon monoxide than others Early signs of carbon monoxide poisoning resemble the fl...

Page 3: ...ecurely to ensure mechanical strength and a tight gas seal Repeat for all four legs See Figure 2 NOTE In extremely low fireplaces or where andirons are being used the LEGS may be left off HOWEVER TO PREVENT GAS LEAKING BENEATH THE BURNER PAN THE NUT BOLT AND FIBER WASHER MUST BE INSTALLED TO ENSURE GAS TIGHT INTEGRITY Standard Match Lighted For use only with Natural Gas Models CS CS W WARNING A SA...

Page 4: ...o BURNER PAN AIR MIXER CA CA W or BURNER PAN REDUCING COUPLING CS CS W and using wrench placed onto VALVE at the WRENCH ATTACH POINT tighten to the position shown at Figure 7 C Attach Pilot Thermocouple 1 Align the PILOT THERMOCOUPLE ASSEMBLY on side of BURNER PAN as shown in Figure 7 Using NUT and BOLT through pre punched hole in side of burner pan attach ANGLE BRACKET ensuring that the PILOT BUR...

Page 5: ...nd to the FLARED BURNER INPUT FITTING D Wrench tighten Figure 12 NOTE If bent into too small a radius the ALUMINUM CONNECTOR TUBE C may kink or break causing air flow noise and or leaks 4 Turn gas supply to fireplace on 5 Test all connections for leaks with soapy water solution If solution bubbles turn off gas supply re tighten fitting and recheck WARNING DO NOT FLAME TEST FOR LEAKS STEP FOUR Whit...

Page 6: ...PLY VALVE completely MANUAL MATCH LIGHTING WITH ACCESSORY V17 VALVE Match Lighted V17 Valve Applies only to Natural Gas Models CS or CS W 1 Ensure that MANUAL V17 VALVE is completely closed See FIGURE 5 2 Open FIREPLACE GAS SUPPLY VALVE See FIGURE 7 3 Place lighted match on embers near inlet end of burner DO NOT HOLD MATCH IN HAND 4 Slowly open MANUAL V17 VALVE and wait for burner to light 5 Adjus...

Page 7: ...fference between hot tip and cold junction base Check that thermocouple assembly is installed on side of burner on bracket per instructions Check that only tip of thermocouple is in main burner flame Remove then replace logs to alter heat radiation pattern Ensure that glass doors are open Ensure that proper size gas log set is installed Too large of a set decreases cooling air flow ACCESSORY RPK1 ...

Page 8: ...mages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contr...