GENERAL INSTALLATION INSTRUCTIONS
ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS FOR RASMUSSEN
VENTED CUSTOM PAN BURNER MODELS:
CS; CS-W (Wide) for use with Natural Gas
CA; CA-W (Wide) for use with Propane (LP) Gas
IMPORTANT
READ THESE INSTRUCTIONS CAREFULLY BEFORE
STARTING INSTALLATION OF LOG SET.
WARNING:
Improper
installation,
alteration, service or maintenance can cause
injury or property
damage.
Read
these
instructions thoroughly before installation. For
assistance or additional information, consult
your gas log dealer, qualified installer, service
agency or gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use
any phone in your building.
•
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
•
If you cannot reach your gas supplier, call the
fire department.
IMPORTANT INFORMATION
THIS GAS LOG SET MUST BE INSTALLED IN A FULLY VENTED
SOLID-FUEL BURNING FIREPLACE WITH A WORKING FLUE
CONSTRUCTED OF NON COMBUSTIBLE MATERIAL.
The minimum permanent free opening of the fireplace chimney or chimney damper must be at least 39 square inches
based on a minimum chimney height of at least 8 feet. The area of the flue must not be less than 1/10 the area of the
fireplace opening. The flue must exhaust all products of combustion.
The chimney damper must be fixed in a manner to maintain permanent free opening as outlined above at all times. To
accomplish this, install the damper clamp (provided) on the edge of the damper blade to prevent
its closing, drill a hole or holes in the damper, or remove damper completely.
The minimum size of the fireplace in which the log set is to be installed must be as follows:
MINIMUM FIREPLACE SIZE IN INCHES
LOG SET SIZE
HEIGHT
D E P T H
WIDTH
CHIMNEY
18 INCH
24 INCH
30 INCH
.
16
16
16
.
13
13
13
.
24
32
36
.
7 INCH DIAMETER
7 INCH DIAMETER
8 INCH DIAMETER
.
Glass doors must be wide open when burner is lighted
to allow air for safe combustion and venting.
THIS BURNER IS FOR USE IN FULLY FUNCTIONING WOOD BURNING
FIREPLACE WITH THE DAMPER WIDE OPEN.
THE FLUE MUST VENT ALL PRODUCTS OF COMBUSTION.
.