Safety Precautions

 

  

Technician Notes

 

  Only authorized technicians should attempt to repair this equipment.

 

 

Before installing this system, carefully read all the manuals included with the system.

 

 

All repair procedures allow only module replacement. Because of the 

complexity of the individual boards and sub-assembles, no one 

should attempt to make repairs at the component level or make 

modifications to any printed wiring board. Improper repairs can create 

a safety hazard.

 

 

To reduce the risk of personal injury from electric shock and hazardous 

energy levels, do not exceed the level of repairs specified in these 

procedures.

 

 

The system is designed to be electrically grounded. To ensure proper 

operation, plug the AC power cord into a properly grounded AC outlet 

only.

 

 

  

Electrostatic Discharge Precautions

 

 

Electrostatic discharge (ESD) can damage static sensitive devices or 

micro circuitry. Proper packaging and grounding techniques are 
required to prevent damage.

 

 

Keep electrostatic-sensitive parts in their containers until they arrive 

at a static free work area.

 

 

Use a wrist strap connected to the work surface as well as properly 

grounded tools and equipment

 

 

 

Keep the area free of nonconductive materials such as ordinary 

plastic tools and foam packing.

 

 

Avoid touching pins, leads, or circuitry.

 

 

Always place drives with printed circuit board (PCB) assembly-side down.

 

 

Grasp cards and boards by the edges. Hold drives by the frame. 

Avoid touching the solder joints or pins.

 

Summary of Contents for AI161MT

Page 1: ...ATION This document contains confidential information that is proprietary to Rasilient or confidential information which Rasilient has a legal duty to protect from disclosure The information contained in this document may not be disclosed without the express written permission of Rasilient Systems Inc ...

Page 2: ... herein Nothing herein may be construed as granting any right or license relating to any intellectual property rights of this manual or product Unless otherwise provided in the Purchase and Sale Agreement for this product manufacturer and distributor of this product will not be liable whatsoever relating to the distribution and or use of this product In addition manufacturer and distributor of thi...

Page 3: ...nformation 8 Introduction 10 Audience Assumptions 11 About This Guide 11 Product Introduction 12 Powerful 12 Purpose built 12 Effortless installation 12 Complete Security Solution 12 System Specification 13 Hardware Details 14 Front panel 15 Rear panel 16 Configuration Plan 19 Before Deployment 19 Packing Checklist 20 ...

Page 4: ...List of Figures Figure 1 Front View 15 Figure 2 Rear Panel 16 Figure 3 Rear Panel I O 17 Figure 4 LAN LEDs 17 Figure 5 Audio Ports 18 ...

Page 5: ...1 About This Manual Conventions Safety Symbols Safety Precautions Regulatory and Integration Information ...

Page 6: ...ughout this manual Warning Provides Information to prevent injury in the process of completing a task Caution Provides Information to prevent damage to the components in the process of completing a task Important Provides Information required for completing a task Note Provides Tips to aid in completing a task ...

Page 7: ... Component To reduce risk of injury from a hot component allow the surface to cool before touching WARNING Insert Network Interface Only Any receptacle e g RJ45 marked with this symbol indicates a network interface connection To reduce the risk of electric shock fire or damage to equipment do not plug telephone or telecommunications connectors into this receptacle WARNING This symbol on power supp...

Page 8: ...component exceeds the recommended weight for one individual to handle safely To reduce the risk of personal injury or damage to the equipment observe local occupational health and safety requirements and guidelines for manual material handling ...

Page 9: ...stem is designed to be electrically grounded To ensure proper operation plug the AC power cord into a properly grounded AC outlet only Electrostatic Discharge Precautions Electrostatic discharge ESD can damage static sensitive devices or micro circuitry Proper packaging and grounding techniques are required to prevent damage Keep electrostatic sensitive parts in their containers until they arrive ...

Page 10: ...sure that the rack is adequately stabilized prior to extending a component outside the rack A rack may become unstable if more than one component is extended Extend only one at a time Do not stand or step on any components in the rack If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore considerati...

Page 11: ...imes Unplug the power cord from the power supply module to shut off power to the equipment Protect the storage system from power fluctuations and temporary power interruptions witha regulating uninterruptible power supply UPS This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system operational during a power failure The storage system must always...

Page 12: ...Class B devices have an FCC logo or FCC ID on the label Once the class of the device is determined refer to the following corresponding statement This equipment is assembled with components that have been tested and found to comply with the limit pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operat...

Page 13: ... be rated for the product and for the voltage and current marked on the product s electrical ratings label The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product In addition the cross sectional area of the wires must be a minimum of 1 00mm or 18AWG and the length of the cords must be between 1 8m 6 feet and 3 6m 12 feet If you have qu...

Page 14: ...10 Chapter 1 Introduction Audience Assumptions About This Guide Product Introduction System Specifications ...

Page 15: ...and maintain the AI161MT Analytic Server This manual is generally organized as follows General introduction to the AI161MT and its components What you need to do before you start Detailed description of each hardware module and instructions for installation and removal Initializing your system setting up your system on a network configuring your storage and connecting hosts Ongoing usage and maint...

Page 16: ...ration server built around the high performance Intel i7 i9 processor Purpose built Open platform to integrate Video Management Software All major supported Video Management Software providers are prequalified More are continually added to ensure the widest possible certification coverage Effortless installation Effortless installation management and administration along with advance RAID Complete...

Page 17: ... GbE Display Outputs 1x HDMI 1x DVI D 1x VGA On Board I O 2x USB 3 1 2x USB 2 0 Keyboard and Mouse PS2 HDMI DVI VGA 1x USB 3 1 type C Compliance Safety UL IEC 106950 power supply EMI FCC CE Motherboard Power Supply Physical Characteristics Dimensions in mm 10 63 x 8 35 x 15 47 270 x 212 x 393mm Weight 20 lbs 9 kg Power Single Voltage 110 220V AC Watts 620W Operating Environment Operation temperatu...

Page 18: ...14 Chapter 2 Hardware Details Front Panel Rear Panel ...

Page 19: ... displays a simple yet stylish front panel with easily accessible features The power and reset buttons LED indicators and two USB ports microphone and speaker jack are located on the top side of front panel Figure 1 Front View ...

Page 20: ...16 Rear panel The rear panel includes a slot for the motherboard rear I O ports expansion slots a chassis lock and intrusion switch a vent for the system fan and power supply module Figure 2 Rear Panel ...

Page 21: ...17 Figure 3 Rear Panel I O Figure 4 LAN LEDs ...

Page 22: ...18 Figure 5 Audio Ports ...

Page 23: ... IP addresses The simple online configuration procedures will allow you to set up your system on your network using these IP addresses Be sure to ask your network administrator to provide you with sufficient IP addresses for your planned configuration Your administrator should provide the following information so that you can properly configure your system on your network IP Address s Gateway addr...

Page 24: ...m is damaged or missing please contact your sales representative for a replacement The AS 61SSD is shipped with the following Check your system package for the following items Model Name AI161MT Chassis Mini tower chassis Component AS61 Mini tower 1 x 620W Power Supply Accessories 1 x AC Power Cable ...