4. DMX Controller
If control by DMX controller, then you need to set the address code to control the
light, the address code value is 1-512, the light could receive the signal
accordingly. Press
MENU
button select ! menu, press
ENTER
button, address will
strobe. Use
UP /DOWN
to select DMX512 address. After address ensure press
ENTER
button until address stop strobe, After 8 seconds will return the menu. If
return the former but not change, press the menu button.
DMX512 controller output connect the first machine DMX input, then first
machine output connect the second machine DMX input and so on, until you
connect all slave machine.
If you need to extend DMX signal lines, male and female 3pin XLR socket should be
pin 1 to pin 1, pin 2 to pin 2 and pin 3 to pin 3. If not, it will easy to lose signal.
(Notice: each signal lines pin at least 0.5mm, it is better to use Dual-core shielded
cable)