CC-SG V1 Quick Setup Guide 

QSG-CCV1-0O-v5.2.0-E 

 255-80-5110-01-RoHS 

 

II. Rack-mount CC-SG 

 

Identify Rail Sections 

Your rack mount kit contains two rack rail assemblies. Each 
assembly consists of two sections: an inner fixed chassis rail 
(A) that secures to the unit and an outer fixed rack rail (B) that 
secures to the rail brackets. A sliding rail guide sandwiched 
between the two should remain attached to the outer fixed 
rack rail. The A and B rails must be detached from each other 
for installation. 

To remove the inner fixed chassis rail (A), pull it out as far as 
possible until you hear a clicking sound when a locking tab 
emerges from inside the rail assembly and locks the inner rail. 
Depress the locking tab to pull the inner rail completely out. 
Do this for both rack rail assemblies. 

 

Install the Chassis Rails 

1.  Position the inner fixed chassis rail sections you just 

removed along one side of the chassis; ensure the five 
screw holes line up.   

2.  Screw the rail securely to the side of the chassis. 

3.  Repeat steps 1 and 2 for the other rail on the other side of 

the chassis. Attach rail brackets if installing into a Telco 
rack. 

 

Install Rack Rails 

1.  Determine where you want the CC-SG belongs in the 

rack. 

2.  Position the outer fixed rack rail/sliding rail guide 

assemblies at the desired location in the rack, keeping the 
sliding rail guide facing the inside of the rack. 

3.  Screw the assembly securely to the rack using the 

brackets provided. 

4.  Attach the other assembly to the other side of the rack, 

making sure that both are at the exact same height and 
with the rail guides facing inward. Ideally, two people 
should work on this together. 

 

Install CC-SG into the Rack 

Once the rails are attached to both the chassis and the rack, 
install CC-SG into the rack. 

1.  Line up the rear of the chassis rails with the front of the 

rack rails. 

2.  Slide the chassis rails into the rack rails, keeping the 

pressure even on both sides (you may have to depress 
the locking tabs when inserting). When CC-SG has been 
pushed completely into the rack, you should hear the 
locking tabs click. 

Locking Tabs 

Both chassis rails have a locking tab that serves two 
functions: 

 

To lock CC-SG into place when installed and pushed fully 
into the rack (normal operating position). 

 

To lock CC-SG in place when extended from the rack, 
preventing the unit from falling out of the rack when pulled 
out for servicing. 

 

QS R ule 

 

III. Connect Cables 

Once the CC-SG unit is installed into the rack, you can 
connect cables. See the diagrams on page 1. 

1.  Connect the CAT 5 network LAN cable to the LAN 1 port 

on the rear panel of the CC-SG unit. It is strongly 
recommended to connect a second CAT 5 network LAN 
cable to the LAN 2 port. Connect the other end of each 
CAT 5 cable to the network. 

2.  Attach the included AC power cord to the power port on 

the rear panel of the CC-SG unit. Plug the other end of the 
AC power cord into an AC power outlet. 

3.  Connect KVM cables to the corresponding ports on the 

rear panel of the CC-SG unit. 

 

QS R ule 

 

IV. Log in to Local Console to Set CC-SG IP 
Address 

1.  Power ON CC-SG by pressing the POWER button on the 

front of the CC-SG unit.   

2.  Attach the front bezel by snapping it onto the front of the 

CC-SG unit. 

3.  Log in as 

admin/raritan

. Usernames and passwords are 

case-sensitive. 

4.  You will be prompted to change the local console 

password. 

a.  Type the default password (

raritan

) again. 

b.  Type and then confirm the new password. The new 

password must be a strong password consisting of at 
least eight characters that are a combination of letters 
and numbers. 

5.  Press CTRL+X when you see the Welcome screen.   

6.  Choose Operation > Network Interfaces > Network 

Interface Config. The Administrator Console appears.   

7.  In the Configuration field, select DHCP or Static. If you 

select Static, type a static IP address. If needed, specify 
DNS servers, netmask, and gateway address.   

8.  Select Save. Wait a few minutes as CC-SG restarts. 

 

Default CC-SG Settings 

IP Address: 192.168.0.192 

Subnet Mask: 255.255.255.0 

Username/Password: admin/raritan 

 