background image

6

Mounting Toilet

Mounting surface must be flat and solid.

1. 

Install seat on toilet (FIG 1).

2. 

Remove motor cover.

3. 

Place toilet where it will be located.

 

Make sure there is room to route hoses.

 

Make sure seat will open properly (FIG 2).

4. 

Mark location of toilet base mounting holes on 

mounting surface (FIG 1).

5. 

Drill holes for toilet mounting bolts/screws.

NOTE:

  Hole size will depend on type of bolt/screws 

used (5/16” [8 mm] size bolts/screws are recommended).

6. 

Secure toilet to surface

       Additional Parts Required  

• 

 Four stainless steel mounting bolts or lag screws 

(minimum 1/4” [6mm]) and washers.

•   1” (25mm) or 1 1/2” (38mm) I.D. discharge hose. 

• 

 3/4” (19mm) for seawater models or 1/2” (13mm) 

for freshwater models, reinforced intake hose. 

• 

 Hose clamps (two for each connection below 

waterline). 

• 

 Wire.

• 

 Terminals. 

• 

 Fuse/circuit  breaker.

Parts 

Included 

    

All Complete Toilets

 

   

Toilet 

Bowl 

 

    

Seat 

and 

Cover 

    

Lower Base Assembly 

 

 

 

Motor 

Cover 

     

1 1/2 (38mm) 90° Discharge fitting   

 

 

Adapter, 1” FPT x Barb   

 

 

 

Control 

     

Sea Water Model

 

    

Intake 

Pump 

     

3/4” Hose Barb - straight fitting (2)   

 

 

3/4” Hose Barb - 90° fitting 

 

 

Plug Fitting

90° Rotation of Toilet Bowl

Toilet bowl can be rotated 90° on the base, for installing in 

confined locations (FIG 3).  
1. 

Determine which direction bowl is to be mounted.

2. 

Remove four vinyl caps at the base of toilet bowl.

3. 

Remove four nuts and shoulder washers.

4. 

Carefully remove toilet bowl from base.

5. 

Rotate toilet bowl to desired position.

6. 

Replace four shoulder washers, nuts and vinyl caps.

NOTE:

  Tighten nuts carefully and evenly.  Do

Not over tighten.

Install the Warning Label (L322) where it can be easily 

seen.

Mounting In-Line Strainer 

(Seawater Models Only)

Make sure strainer bowl is tight.

1. 

Locate strainer where it will be accessible.

2. 

Mark and drill mounting holes.

      NOTE:    Hole  size  will  depend  on  type  of  bolts/screws  used               

 

  (1/4” [6mm] size bolts/screws are recommended).

3. 

Install fittings provided (PLA14) on strainer’s inlet and 

outlet ports.

   NOTE:  Use thread sealant.

4. 

Mount strainer.  Hoses must be installed according to flow 

marking on strainer top.

Mounting Remote Intake Pump 

(Remote Pump Models Only)

1. 

Remote intake pump must be mounted on a flat solid surface 

in an area that is dry and well ventilated.

2. 

Mark and drill mounting holes.

   NOTE:  Hole size will depend on type of bolts/screws used         

 

   1 /4” [6mm] size bolts/screws are recommended).

3. 

Mount pump.  Do not over tighten bolts.

INST

ALLA

TION 

       Tools Required

• 

5/16” nut driver, wrench or screw driver. 

•  5/8” (16mm) drill bit, bit for drilling mounting surface, 

wire cutters, wire terminal crimpers, hose cutters, tape 

measure.

L365v0320jlc 

FIG 1

FIG 2

FIG 3

Summary of Contents for SeaEra QC Series

Page 1: ...ed in 46CFR 110 15 65 e Subchapter J Electrical Engineering DO NOT run continuously for more than 30 seconds WARNING HAZARD OF FLOODING Always shut off seacock s before leaving the boat unattended Dou...

Page 2: ...equirements No special toilet paper is required Water should appear in the bowl within ten seconds If not see troubleshooting section Hard objects or stringy substances paper towels feminine hygiene p...

Page 3: ...I D intake hose approximately 3 feet 1 m long 1 25 mm or 1 1 2 38 mm I D discharge hose approximately 3 feet 1 m long Two buckets Nontoxic antifreeze approximately 1 quart 1 liter Steps 1 Close the i...

Page 4: ...52 11 1 2 292 20 508 14 3 8 365 INCHES MM NOTE 1 THE SEAT WILL OPEN WITHIN THE DEPTH OF THE BOWL D HOWEVER IT MAY BE DESIRABLE TO INCREASE THIS ANGLE BY ALLOWING MORE ROOM AT THE BACK OF THE BOWL FOR...

Page 5: ...tal distance Same wire size MUST be used for lower base and remote intake pump 3 Recommended conductor wire minimum AWG mm2 for 3 voltage drop 4 Recommended conductor sizes are based on 105o C rated i...

Page 6: ...3 1 Determine which direction bowl is to be mounted 2 Remove four vinyl caps at the base of toilet bowl 3 Remove four nuts and shoulder washers 4 Carefully remove toilet bowl from base 5 Rotate toilet...

Page 7: ...nforced hoses Secure all hoses properly Pressurized Freshwater Model Installed Above Waterline SeaEra Toilet Discharge Holding Tank Pressurized Freshwater Source Waterline Shut off Valve 1 1 2 38mm Di...

Page 8: ...stalled Use hose clamp provided 7 Connect hose from outlet port of In Line Strainer to inlet port of intake pump Use hose clamp provided IMPORTANT Double clamp all below waterline hose connections 8 C...

Page 9: ...inconsistent voltage 1A Be sure discharge seacock is open Clear line remove clog 1B Replumb to eliminate bends and ells 1C Clean holding tank vent and vented loop vents 1D Clean or replace affected p...

Page 10: ...Fitting 51 190601 Inline Fresh Water Strainer Optional 61 163000 Inline Strainer Optional SeaEra QC model 162 PARTS LIST Additional Parts Included with REMOTE MODELS Item Part Description 27 161135 M...

Page 11: ...11 EXPLODED PARTS SeaEra QC Series Exploded Parts View Optional Sea Water Strainer Optional Fresh Water Strainer L365v0320jlc 84...

Page 12: ...installation of this product defects caused by installation of this product otherthaninaccordancewiththemanufacturer srecommendedinstallationinstructionsorstandard industry procedures physical abuse t...

Reviews: