background image

15

NOTE:
Discharge of raw, untreated sewage is prohibited in all U.S. waters inside the three mile limit except in the Gulf of Mexico
where the limit is nine miles. "Y" valves, if installed, must direct toilet discharge to a U.S.C.G. approved treatment
system or holding tank and must be secured in that position while inside the three-mile limit.

The EPA standards state that in freshwater lakes, freshwater reservoirs or other freshwater impoundments whose inlets or outlets
are such to prevent the ingress or egress by vessel traffic subject to this regulation, or in rivers not capable of navigation by
interstate vessel traffic subject to this regulation, marine sanitation devices certified by the U.S. Coast Guard installed on all
vessels shall be designed and operated to prevent the overboard discharge of sewage, treated or untreated, or any waste derived
from sewage. The EPA standards further state that this shall not be construed to prohibit the carriage of Coast Guard-certified
flow-through treatment devices which have been secured so as to prevent such discharges. They also state that waters where a
Coast Guard-certified  marine sanitation device permitting discharge is allowed including coastal water estuaries, the Great
Lakes and interconnected waterways, freshwater lakes and impoundments accessible through locks, and other flowing waters
that are navigable interstate by vessels subject to this regulation (40 CFR 140.3)

Summary of Contents for PST*02

Page 1: ...product Equipment damage injury to personnel or death could result from improper installation Raritan Engineering Company Inc accepts no responsibility or liability for damage to equipment or injury o...

Page 2: ...ns 5 7 liters per cycle After Toilet is flushed Water is diverted to the tablet dispenser and must rise to the water level line dotted line but no higher The Purasan should not be activated again unti...

Page 3: ...135 CAUTION Tablet dispenser may be under pres sure Open lid SLOWLY Remove used tablet cartridge 1 With adequate ventilation available Unscrew tablet dispenser lid and lift out used tablet car tridge...

Page 4: ...container and pour into toilet bowl Rinse container and dis pose of properly 8 Flush toilet several more times to dilute solution and clear it from system Treatment Unit WARNING DO NOT use anti freez...

Page 5: ...is working properly before proceeding These instructions are the reverse operation outlined in winterizing the Tablet Dispenser steps 3 through 6 1 Remove tube from the bottom of the black T fitting a...

Page 6: ...e s u f r e k a e r B s p m a e z i s w a r d p m A l a n i m o n e g a t l o v 0 1 t e e f 5 1 t e e f 0 2 t e e f 5 2 t e e f 0 3 t e e f 0 4 t e e f 0 5 t e e f C D V 2 1 0 2 0 1 G W A 2 1 G W A 2...

Page 7: ...Unit 4 Attach wires per wiring section to back of switch panel 5 Mount panel using 4 screws Apply a bead of nonpermanent sealant around rear edges of panel if located in shower area Purasan Tablet Dis...

Page 8: ...ct 1 Connect discharge of toilet to one intake port 2 Insert plug or second toilet discharge into other intake port 3 Determine position and glue discharge elbow to top of tank using PVC cement 4 Conn...

Page 9: ...led between source and Purasan on positive wire Switch Panel 1 Connect cable from Switch Panel to Circuit Board as follows S1 to S1 red wire S2 to S2 orange wire L1 to L1 green wire L2 to L2 white wir...

Page 10: ...ntrol Board voiding warranty 2 Run 16 ga wire from small relay terminal to S2 on Circuit board and one post of the PBS push button switch Freshwater dual installation and manual toilets Solenoid valve...

Page 11: ...lenoid for proper operation Intake tubing clogged clean or replace intake tubing Bowl Elbow was not changed install bowl elbow with restrictor supplied Overflow or water level too high in dispenser Me...

Page 12: ...12 EXPLODED PARTS 10 17 18 8 7 21 63 64 56 43 45 6 42 43 47 49 32 31 29 28 53 23 55 50 23 23 24 22 41 100...

Page 13: ...r Hold down Bolt 10 32x1 S S 4 9 31 109 Mixer Impeller 10 31 110 1 Impeller Bolt 12 24 x 5 8 S S 2 11 31 110 2 Impeller Lock Washer 12 S S 2 12 31 114 Cover Hold down Nut 10 32 18 13 31 115 Treatment...

Page 14: ...tarts treatment cycle Flushing toilet will activate treatment cycle Note Toilet may be flushed as often as necessary do not exceed recommended flush volume 1 Mount Switch Panel near toilet CAUTION Use...

Page 15: ...traffic subject to this regulation marine sanitation devices certified by the U S Coast Guard installed on all vessels shall be designed and operated to prevent the overboard discharge of sewage trea...

Page 16: ...ls or workmanship supplied by others in the process of installation of this product defects caused by installation of this product other than in accordance with the manufacturer s recommended installa...

Reviews: