Raritan PMC-1000 Quick Setup Manual Download Page 20

 
 

 

 

Power Meter Quick Setup Guide 

20 

QSG-PMM-1A-v3.3.10-E 

 255-64-0004-00 

 
 
 

 

 

Using the PMM's Display 

 

Automatic Mode: 

The PMM has a display with automatic and 

manual modes. In automatic mode, the display 
scrolls through readings.   

 

 

 

Manual Mode: 

In manual mode, you can select readings and 

settings to view.   

Press 

  or 

  to view the Main Menu.   

To return to automatic mode, press 

  once 

or several times. 

Press 

 

  to choose a menu item. Press 

  to select.   

 

 

Power Meters list   

 

   

 

Power Meter details 

 

 

 

Summary of Contents for PMC-1000

Page 1: ...llution Degree 2 environment must control conductive pollution and the possibility of condensation or high humidity Consider the enclosure the correct use of ventilation thermal properties of the equi...

Page 2: ...to 70 PMM or 8 PMM PMB Interconnection uses standard shielded CAT 5 cable All modules receive redundant power and continue to function as long as one or more PMM remain powered Raritan PM series power...

Page 3: ...63 Hz Input Impedance 10M Ratings for models with field wiring terminals For models with factory installed line cords rating is limited by plug and ratings are labeled on back on unit Current Measure...

Page 4: ...240V Current 0 2A Overvoltage Category CAT III Pollution Level 2 Frequency 47 63 Hz Mechanical Terminal Block Screw Torque 0 37 ft lb 0 5Nm to 0 44 ft lb 0 6Nm Terminal Block Wire Size 14 24AWG 5 1 6...

Page 5: ...Controls TOP A Voltage measurement B Power C Factory use do not connect D Meter Bus Terminator Switch E Meter Bus Connectors Connects PMM to controller F Factory use do not connect G Multi conductor c...

Page 6: ...le CT 1 connector 2 Multi conductor cable CT 2 connector 3 Multi conductor cable CT 3 connector 4 Multi conductor cable CT 4 connector 5 Multi conductor cable CT 5 connector 6 Multi conductor cable CT...

Page 7: ...d RS 485 B Meter bus connector to PMM C Meter bus terminator switch D 10 100 base t Ethernet E Feature port Raritan asset strip F Sensor port temperature humidity etc G USB A B flash drives WIFI seria...

Page 8: ...ion Connector supplied with PMB Do not hot plug the Expansion Port PMM and PMB must be disconnected from all power source before plugging Expansion Port Snap Expansion Connector to Expansion Ports on...

Page 9: ...d Do not solder tin wire ends C All CT 333mV output at rated current Do not use current output CT CTs can be connected to live circuits Connect CT in either direction Circuit Type Circuit Description...

Page 10: ...eled connector All CTs 333mV output DO NOT use current output CT CT can be connected to live circuit in either direction Meter auto corrects polarity Branch Circuit Description Current Transformers Ho...

Page 11: ...an auxiliary AC power source Powering from the voltage measurement inputs minimizes circuitry but the meter may stop functioning if the voltage turns off Powering from an auxiliary single phase circu...

Page 12: ...sy chain wired to a single controller PMC using shielded cat 5 Ethernet cable The wiring order of the modules and controller is not important A All cables shielded Cat 5 each cable 100m max length B S...

Page 13: ...Power Meter Quick Setup Guide 13 QSG PMM 1A v3 3 10 E 255 64 0004 00 Panel Layout...

Page 14: ...ow 30 seconds for first connection Username admin Password raritan Configuring Power Meters and Branch Circuit Monitors You can configure your product with a spreadsheet or in the product s web interf...

Page 15: ...ut PMB 1 Enter a name 2 Select the circuit type Single Phase Split Phase 3 phase 3 Enter the mains circuit breaker rating 4 Select the checkbox for each CT installed Enter the CT rating Ratings are ma...

Page 16: ...Split Phase 3 phase 3 Enter the number of circuit positions in the panel Select the panel layout one or two columns Select the circuit position numbering style sequential or odd even 4 Enter the curr...

Page 17: ...position to open the pop up menu 3 Click Create Circuit The Create Circuit dialog opens 5 Enter a name for the circuit 6 Select the circuit type One Phase LN One Phase LL One Phase LLN or Three Phase...

Page 18: ...th a black bracket around the circuit positions Configure Thresholds 1 In the Power Meters page click the panel or power meter The details page opens 2 In the details page click the actions icon then...

Page 19: ...255 64 0004 00 4 Select the checkbox for the level and enter the threshold current in amps Click OK This example shows RMS Current thresholds set for upper warning and critical levels for the circuit...

Page 20: ...with automatic and manual modes In automatic mode the display scrolls through readings Manual Mode In manual mode you can select readings and settings to view Press or to view the Main Menu To return...

Reviews: