background image

12

D. WIRING

WARNING:  Hazard of Shock and Fire

Always use proper wire, wire connectors and
fuse/circuit breaker.  See Specification
Chart.

Secure wire properly.

Do not connect appliances to toilet circuit.

Make sure power is off before proceeding.

Use proper wire terminals for all wire
connections.

1. Determine proper wire size by measuring distance

from:

Power Source to push button to toilet motor
and back to power source.

Remote pump units - also include distance
from power source for remote pump to
remote pump and back.  Same wire gauge
must be used for both lower base and remote
pump.

2. Select proper wire and fuse/circuit breaker size

from Specifications on Installation page.

3. Install fuse/circuit breaker in positive line at source.

4. Wire control to the toilet and battery using one of

the following wiring diagrams.

WIRING

To start Electroscan from  toilet control, run a wire
from “to EST “ to terminal marked “EXT TRIG”
inside Electroscan control module (black box).
To start Elegance equipped with Smart  Switch  from
Electroscan, connect “Head1” to “FROM EST “.
For Lectra/San MC, call Raritan Customer Service

ELECTROSCAN OPERATION

Smart Flush Control

Fig. 13

CUT

OUT

Summary of Contents for Elegance

Page 1: ...gonlytheabilityto flushwithnoindependantcontrolofwateror Marine Elegance Elegance Elegance Elegance Elegance THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLA...

Page 2: ...pinstalled between the intake pump and the toilet bowl Doubleclampallbelowwaterlineconnections Recommended Visual Inspection 3 3 3 3 3 For leaks at toilet and hose connections 3 3 3 3 3 Hoseclamps 3 3...

Page 3: ...to evacuatethebowl Dischargepumprunsas longasthisbuttonisheld 2 Water Only Press Water Only switch to addwaterinthebowl Inletwatersolenoid pumprunsaslongasbuttonispressedwith asevensecondslimit After...

Page 4: ...retention fill Time After placing the unit in program mode Step 1 above push the WATER ONLY button the number of times required for the Water Valve Inlet Pump time one push ZERO sec s two 1 sec three...

Page 5: ...et 1m long 1 25 mm or 1 1 2 38 mm I D discharge hose approximately3feet 1m long Two buckets Nontoxicantifreezeapproximately1quart 1liter Steps 1 Close the intake and discharge seacocks 2 Turnoffpowert...

Page 6: ...2 p o r d e g a t l o v 3 r o f 4 5 0 1 n o d e s a b e r a s e z i s r o t c u d n o c d e d n e m m o c e R o n o i t a l u s n i d e t a r C s g n i t a r n o i t a l u s n i r e h t o r o f s d r...

Page 7: ...dist 7 8 Hence a maximum of 7 high loop can be installed 6 4 2 0 20 40 60 80 100 0 120 140 160 180 Horizontal distance Feet Marine Elegance discharge Maximum recommended 1 PVC hose length Parts inclu...

Page 8: ...ket assembly to deck using 14 self threading bolts and flat washers Note place bolts as close to mark linesA B and C as possible 5 Drill holes for discharge 1 5 8 41 mm inlet hose 7 8 22mm andwires 3...

Page 9: ...lampallbelow waterlineconnections IMPORTANT Fittings and 90 bends should be kept to a minimum In Line Strainer may be installed on Sea Water Models per Installation Instructions This will prevent clog...

Page 10: ...ed 1 Slidefittingclipstoopenposition 2 Select inlet port to be used 3 Installappropriatefittingsintoinletandoutletports NOTE The 90 fitting can be rotated 360 4 Installtheplugfittingintounusedinletpor...

Page 11: ...g holesusingwallplateasguide 2 Route wire to the toilet and control 3 Securecontrolwithgasketusingtwo screws C Smart Flush Control 1 Cut out a hole per Fig 13 mark mounting holesusingwallplateasguide...

Page 12: ...power source for remote pump to remote pump and back Same wire gauge mustbeusedforbothlowerbaseandremote pump 2 Select proper wire and fuse circuit breaker size fromSpecificationsonInstallationpage 3...

Page 13: ...noid valve Discharge pump Fig 14 Wiring for Push Button Switch Fresh water model To EST Discharge pump Black RED Blue Blue Black RED Fuse Pump Relay RED Push Button Push Button BATTERY 13 Fig 14A Wiri...

Page 14: ...L PANEL FUSE BREAKER orange black red black red black panel tankfullswitch ESTinput BATT FLUSH CONTROL PANEL FUSE BREAKER Relay PUMP remote Fig 15 WIRINGFOR SMART SWITCH FRESHWATER MODEL Fig 16 WIRING...

Page 15: ...Breaker red orange black blue black red RED Relay Fig 18 WIRING FOR ME TOILET CONTROL WITH REMOTE PUMP Fig 17 WIRINGFOR ME TOILET CONTROL FRESHWATER MODEL Solenoid Valve Discharge Pump Discharge Pump...

Page 16: ...necthosesandwireplugs see Fig 19 Caution Do not pull on the discharge hose to avoid kinking 8 Installmountingbushings bolts SeeFig 20 9 Tightenboltsbeingcarefultonotovertighten Do notexceed30inchlb wh...

Page 17: ...chargeline 4A Pressurebuildupatseacocks 5A LeakingBowlThroatadapter 5B Leakatshaftseal 5C Leak from bowl spud SOLUTION 1A Besuredischargeseacockisopen Clearline remove clog 1B Replumbtoeliminatebendsa...

Page 18: ...F195 Front mounting washer 1 F196 Front mounting snap cap 1 M23A Lockwasher 166000 Remote pump complete 12v 166100 Remote pump complete 24V 1660 Motor raw water pump 161115 Impeller 161123 Macerator...

Page 19: ...5 162225 162135 162100W 162420 162200W 190601 Recommended EXPLODED PARTS F193 freshwater strainer Recommended Seawater strainer 19 FIG 21 221100 F186VT 221210 221110 221150 221300 161123 161115 31 102...

Page 20: ...psupplied byothersintheprocessofinstallationofthisproduct defectscausedbyinstallationofthisproduct otherthaninaccordancewiththemanufacturer srecommendedinstallationinstructionsorstandard industryproce...