Mounting controls:
A. Mounting control box:
1.
Locate a place for control box near toilet. Do not install
box more than six feet away to avoid excessive voltage
drop
2. Route wires between toilet and control
B. Switch Panel:
1. Cut out a hole per Fig. 1, mark
mounting holes using wall plate as guide.
2. Route wire to the toilet and control.
3. Secure control using sealant with two
screws.
C. Sea/fresh control:
1.
Follow Switch Panel instructions above.
Fig.1
WIRING
2
Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size
Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size
NOTES: for Wiring
1.
Distances are from source to unit and back to source.
2.
Distance from power source to remote intake pump MUST be
included when determining total distance.Same wire size MUST be
used for lower base and remote intake pump.
3.
Recommended conductor wire minimum AWG (mm
2
) for 3% volt-
age drop.
4.
Recommended conductor sizes are based on 105
o
C rated insulation.
Refer to ABYC Standards for other insulation ratings.
5.
For 120/240 VAC units use 12VDC specifications from transformer
to unit.
Feet
10
15
20
25
30
40
50
Meter
3.1
4.6
6.1
7.6
9.2
12.2
15.2
CONVERSIONS
Wire - AWG to mm
2
Feet to Meters
AWG
16
14
12
10
8
6
4
2
mm
2
1.5
2.5
4.0
6.0
10.0
16.0
25.0
35.0
Units
Voltage
Circuit
Breaker/fuse
size (amps)
Discharge
Amp. draw
Remote Pump
Only
Amp. draw
15
feet
20
feet
30
feet
40
feet
50
feet
Atlantes
Marine Elegance
12 VDC
30
18
10
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
SeaEra
25
13
10
Atlantes
Marine Elegance
24 VDC
20
10
5
14 AWG
14 AWG
12 AWG
10 AWG
10 AWG
SeaEra
15
7.5
5
Units
Voltage
Circuit
Breaker/fuse
size (amps)
Amp.
draw
10
feet
15
feet
20
feet
30
feet
40
feet
50
feet
Atlantes
Marine Elegance
12 VDC
25
18
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
SeaEra
25
13
Atlantes
Marine Elegance
24 VDC
15
10
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
SeaEra
15
7.5
L483 0216jlc