R00190
Wolseley UK, CV31 3HH
0344 292 7060
[email protected]
www.raptortool.co.uk
Before using the instrument, please read this manual
carefully and save for future reference.
R00186
SINGLE INPUT K TYPE THERMOMETER
USER MANUAL
Page 1: ...R00190 Before using the instrument please read this manual carefully and save for future reference R00186 SINGLE INPUT K TYPE THERMOMETER USER MANUAL...
Page 2: ...tion manual safe for future reference Warning A Warning identifies conditions and actions that pose hazards to the user To avoid electrical shock or personal injury follow these guidelines 1 Before us...
Page 3: ...obes on or near live apparatus 6 Do not place the thermometer handset near to hot objects 7 Reflective objects result in lower than actual temperature measurements These objects pose a burn hazard 8 R...
Page 4: ...ation The thermometer has built in cold end compensation This will allow the thermometer to automatically compensate between ambient temperature within the thermometer and the cold end temperature of...
Page 5: ...he integrity of measurements Wolseley recommends that the thermometer is calibrated annually at an approved Calibration Laboratory Wolseley can offer this service please contact calibration raptortool...
Page 6: ...uctions Features LCD screen Back Light C F K kelvin functions Data hold function Record Max Min Avg Built in cold end compensation NTC Offset setting 6 C Timer Low battery indicator Auto power off the...
Page 7: ...6 Physical Appearance Power Hold Back Light Settings Record Max Min Avg Unit C F K Kelvin Thermocouple port Built in cold compensation NTC Features Height 127mm Width 58mm Depth 30mm Weight 105g...
Page 8: ...do this will result in an inaccurate reading Select Unit of Temperature Press C F K button to select the unit of measurement C F K Kelvin Display Temperature Place the thermocouple probe in a positio...
Page 9: ...in Avg will display in top right hand side of LCD with actual temperature reading on main screen Use REC button to scroll through Max Min Avg readings The timer will show the actual recorded time of M...
Page 10: ...d in 20 secs or press Back Light button again to turn off Measurement Method Data Hold Press the Hold button to keep the temperature reading on the screen The symbol appears on the screen Fig 4 Press...
Page 11: ...g P Enter the power off setting mode the thermometer will display P 10 Fig 5 use the and keys to select the setting of auto power off time between 5 and 60 minutes long press or key can increase or de...
Page 12: ...rmissible adjustment is 6 C After entering the OFFSET the deviation setting is changed by and key When OFFSET mode is in activation OFFSET will be displayed in the centre of the screen Fig 6 NOTE OFFS...
Page 13: ...is not in use for a long time please take out the batteries to prevent damage caused by leakage Please replace the battery by following these steps 1 Turn off the instrument 2 Remove the battery cover...
Page 14: ...13 Battery Replacement NOTE When the batteries are too low the LCD screen can also show random readings fig 8 Fig 8...
Page 15: ...re Humidity 0 C 40 C 80 RH 10 C non condensing Storage Temperature Humidity 10 C 60 C 70 RH remove the batteries Power Supply 3 x 1 5V AAA Batteries included Technical Handset Temperature Measuring Ra...
Page 16: ...ip This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling WEEE Directive 2012 19 EU At...