Calibration
There are 2 ways to calibrate in
Diamond App
You should get a
“Calibration Successful”
message. Next, tap the
"DONE"
button in the bottom right
corner to save calibration.
Mono – The red azimuth line should go directly down the middle
of the mound. (You should not be able to see the pitching rubber,
so use a person, bat, tee, etc. to ensure the line is lined up correctly.)
Stereo 1 & 2 – Both red azimuth lines should land on the calibration
board.
Note:
if the line on the Mono camera is in line with the middle of the rubber, but the
two Stereo lines are not on the board, make sure the unit is directly in line between
home plate and the mound
.
Settings > Devices > PRO 3.0 > Recalibrate
Play > Recalibrate
(in bottom right corner)
Place the calibration board flush to the front edge of home plate and centered with the middle of the plate.
Ensure the leveling bubble on the top of the board is as close to the center as possible.
1.
2.
Once Calibration is selected, the top LED Displays will show WHITE, and Diamond App will display
calibration streams of all 3 cameras.
3.
After all 3 cameras are lined up, tap the
“Field Calibration”
button in the bottom right corner.
4.
9