7. Operation 

3.1 

AOG 1002/2

 

Before collection waste oil always check how many waste oil is already within the container 

 

by using the level indicator Pos. 4. If the container is full, first empty - refer to chapter 3.1.2.

3.1.1  Waste oil collection
 

For collecting the waste oil place the funnel Pos. 1 as close as possible to screwed drain plug 

 

( max. 550 mm) and secure with hand knob Pos. 3.

3.1.2  Drain
 

Move oil drain cock Pos. 5 over the waste oil tank and open the oil drain cock. Waste oil can 

 

drain off. When the container is empty, shut off the oil drain cock.

3.2 

AOG 1003 Z

 

Before collection waste oil always check how many waste oil is already within the container by 

 

using the level indicator Pos. 4. If the container is full, first empty - refer to chapter 3.1.2

3.2.1  Waste oil collection
 

For collecting the waste oil open drain cock  Pos. 11 under the funnel. Move the funnel as close as 

 

possible to screwed drain plug (max. 550 mm only for AOG 1003) and secure with hand knob 

 

Pos. 3. Hinge drain nozzle Pos. 8 always into the funnel.

3.2.2  Drain
 

Insert the funnel Pos. 3  till the bottom of container and secure with hand knob Pos. 3.

 

Caution!!! 

 It is 

imperative

 to close ball cock Pos.11.

 

Insert the discharge hose  Pos. 10  into the waste oil tank.  Connect the compressed air unit 

 

Pos. 9 to the compressed air line. Now the waste oil container will be drained. 

 

After the operation is finished shut off  compressed air line and exhaust remaining pressure 

 

completely. 

 

Take away the discharge hose (Pos 10)  of waste oil tank and hinge drain nozzle (Pos. 8) to 

 

the holder.  Open ball cock under the funnel.

8. Maintanence and trouble shooting
8.1 

Before every use all parts of the unit which are getting in contact with the medium have to be 

 

checked carefully if there are leaks or damages and if so eliminate.

8.2 

In case of  spilled waste oil pick it up with suitable means and remove it properly. No waste oil 

 

may pollute soil or sewerage system 

8.3 

The pressure reducer is adjusted to 8 bar. In case of higher pressure within the air line, either 

 

reduce the latter or readjust the pressure reducer of device. For this pull out slightly the blue 

 

adjusting cap with pipe wrench and turn until the safety valve acts. Then turn back until the 

 

safety valve closes again. 

8.4 

If oil is leaking at the suction nozzle the container is overfilled.

9. Disposal

9.1  Completely empty  all parts of the equipment ( hoses, pumps , tanks , 
 

etc ) and given case blown out with air .

9.2   Dangerous parts of the appliance must be made unusable f.e. 
 

perforate pressure vessel, deform hose reels , etc.

9.3   rubber , metals, glass ect. must be separated . 
        Dispose material fractions according to the local laws and regulations .

 

YOUR CONTRIBUTION TO PROTECT THE ENVIRONMENT

 

The pertinent regulations for the registration, setting up and operation of equipment for 

 

dealing with materials hazardous to water must always be complied with by the user.

10. Warranty
10.1   In case of insufficient maintenance, faults on operation, use of not adequate spare parts or 
 

attachments all  liabilities and rights of claim under guarantee are void.

10.2   The manufacturer is not liable for improper use of the container or ignoring the safety 
 

instructions.

10.3   Technical modifications are subject to change without announcement.

F a x :   + 4 9   ( 6 1 5 8 )   9 2 9 8 0 - 5 0

[email protected]

Rapid Group GmbH

Bahnhofstraße 53-55

64560 Riedstadt

T49 (6158) 92980-0

www.rapid-group.de

4

+49 (6158) 92980-0

Reviews: