2. General advice

 

ATTENTION !

 

The temperature limits shown apply to the pump components and must 

 

be respected to avoid possible damage or malfunction.

 

ATTENTION ! 

 

Functioning under by-pass conditions is only allowed for brief periods of 

 

time (2-3 minutes maximum).

Given the limited weight and size of the pump (see overall dimensions), moving the pumps does not require the 
use of lifting devices.
The pumps were carefully packed before shippment. Check the packing material on delivery and store in the dry 
place.

3. Technical data

4. Description

The ABP 35 G12 and ABP 35 G24 are electrical Pumps suitable for urea, weak acid and weak alkaline fluid etc. or 
water.

Pump:   Self-priming, volumetric, diaphragm pump, equipped with by-pass valve.
Motor:   Asynchronous motor, single-ohase, 2 pole, closed type (Protectionclass IP 55 in conformance with EN 
 

  60034-5-86 regulations) self ventilated

5. Assembling / Installation

5.1 Disposing of the packing material
 

The packing material does not require special precautions, not being in any way dangerous 

 

or polluting.Refer to local regulations for ist disposal.

5.2   Electrical power suply
5.2.1  During installation and maintenance, make shure that the electric supply lines are not live
5.2.2  Always turn off the switch before supplying electrical power.
5.2.3  Check the connect rotation direction of the DC pump. If it is inverted, 
 

check the polarity of the connection cable.

 

a) RED cable: positive pole (+)

 

b) BLACK cable: negative pole (-)

 

ATTENTION !

 

Power from lines with values outside the indicated limits can damage the   electrical 

 

components.

5.3 Preliminary inspection:
 

- Check that the machine has not suffered any damage during transport or storage.

 

- Clean the inlet and outlet openings, removing any dust or residual packing material.

 

- Make sure that the motor shaft turns freely

 

- Check that the electrical specifications correspond to those shown on the identification 

Model

# 28 265 ABP 35 G12

# 28 265 ABP 35 G24

Operating voltage

12V

24V

Protection class
Working temperature min. / max.
Air humidity max.
Dimensions
Suction hose
Delivering hose
Nozzle
Meter
Noiselevel (1m distance)

80db

-

ca. 296x182x174 mm (LxBxH)

IP 55

-10°C (14°F) / +60°C (140°F)

90%

1,5 m

6 m

manual

+49 (6158) 92980-0

3

Summary of Contents for ABP 35 G12

Page 1: ...of equipment are checked carefully before delivery for their perfect composition and function In case of improper use all rights to claim under guarantee are void i Weiterentwicklung im Sinne des For...

Page 2: ...ed Always wear safety cloths respecting the applicable regulations for accident prevention Only use this device conforming to its purpose and function Improper use can cause severe injuries Caution mo...

Page 3: ...s not being in any way dangerous or polluting Refer to local regulations for ist disposal 5 2 Electrical power suply 5 2 1 During installation and maintenance make shure that the electric supply lines...

Page 4: ...1 or the flow meter Step 3 Flow meter optional Connect the flow meter by the elbow to the outlet of the pump Step 4 Nozzle optional Connect the dispensing nozzle by the clamp to the delivery hose 5 5...

Page 5: ...nstructed to require a minimum of maintenance In any case always bear in mind the following basic recommendations for a good functioning of the pump On a weekly basis check that the tubing joints have...

Page 6: ...e user 10 Warranty 10 1 In case of insufficient maintenance faults on operation use of not adequate spare parts or attachments all liabilities and rights of claim under guarantee are void 10 2 The man...

Page 7: ...7 49 6158 92980 0...

Page 8: ...Fax 49 6158 92980 50 info rapid group de Rapid Group GmbH Bahnhofstra e 53 55 64560 Riedstadt Telefon 49 6158 92980 0 www rapid group de 8 49 6158 92980 0...

Reviews: