background image

Rapid Spray Fire Fighting Unit Operators Handbook

Rapid Spray Equipment by Rapid Spray

REVA 19/03/2019

7

Parts List

#

Parts No.

Description

1

ARLP250VSR

Ø250mm screw lid completed with rim & deal - suits 400 - 600L

ARLP450VSR

Ø450mm lid, rim and seal assembly - suits 800 - 2,500L

2

CAP356660020NB

Ø450mm lid seal only (not shown)

3

AFHW10B036M19

36m fire fighting poly hose reel & adjustable nozzle

4

CFFCP040C

1 1/2” camlock F w/ 38mm hose tail

5

CFFCP040A

1 1/2” camlock adaptor M/F thread

6

CFFCP040H

1 1/2” camlock cap to suit M adapter

7

CAP2452067

2” female to 1 1/2” male reducer

8

CFBR25M20F

1 – 3/4” brass reducing bush for F/F bypass

9

ATPFFB40

40mm foot strainer for F/F quick fill

10

CFGE40M40F

40mm M & F 90º gal elbow male

11

CFNE20M20B

3/4” x 20mm barb poly elbow

12

CFNS20M20B

3/4” x 20mm barb straight

13

CFZS40M40B

28mm hose tail, combination nipple zinc

14

CUUB 38mm

38mm black suction hose

15

CUUC 19mm

19mm clear suction hose

16

APF4900Z

Aussie Fire Chief 2 inch pump w/ GX160 Honda motor

17

ATRV150PT20

Pressure relief valve 3/4” nylon

18

CFYS25N20TC

1 – 3/4” nut & tail

19

ARFB038R

1 1/2” brass tank fitting

20

CFVBB040F040F

40mm 1 1/2” lever ball valve

21

CFVBB040M040FBV19M

40mm 1 1/2” ball valve M/F suit PFUS0400LZ (not shown)

22

CFNW20F

3/4” spinweld flush (not shown)

23

ARB195

Rapid Ball Baffle 195mm to suit 400-600 litre

24

ARB355

Rapid Ball Baffle 355mm to suit 800-2500 litre

25

AMHMCYE

Motor cover to suit Honda motors

26

PTC00400FG

400 litre free standing tank

PTSS00400FG

400 litre cylindrical tank to suit PFUS0400LZ Short

PTC00600FG

600 litre free standing tank

PTC00800FG

800 litre free standing tank

PTC001000FG

1000 litre free standing tank

PTC01200FG

1200 litre free standing tank

PTC01500FG

1500 litre free standing tank

PTC02000FG

2000 litre free standing tank

PTC02500FG

2500 litre free standing tank

27

ASFF00400

Steel frame to suit 400-600 litre

ASFF00400A

Steel frame to suit 400 PFUS0400LZ short

ASFF00800

Steel frame to suit 800 litre

ASFF01200

Steel frame to suit 1200-1500 litre

ASFF02000

Steel frame to suit 2000-2500 litre

28

ARP001

18x200mm mounting pin x 4 suit 400-600 litre

ARP002

18x230mm mounting pin x 4 suit 800-1000 litre

ARP004

24x260mm mounting pin x 4 suit 1200-1500 litre

ARP005

24x330mm mounting pin x 4 suit 2000-2500 litre

Summary of Contents for FIRE RANGER

Page 1: ...Fire Fighting ULTIMATEFIRERANGERUNITS OPERATORS HANDBOOK 400L 2 500L CAPACITIES ...

Page 2: ... 03 Product Risk Assessment 04 Operating Instructions 04 Before Use 04 Operation 05 Decontamination Maintenance 09 Parts Breakdown 09 Fire Ranger 400 2 500L Units 08 Poly Fire Fighting Hose Reel 09 Bottom Fill Kit Contents Warnings Operation 10 Aussie Fire Chief Pump 12 Warranty Registration ...

Page 3: ...ook Rapid Spray Equipment by Rapid Spray REVA 19 03 2019 1 INTRODUCTION Congratulations on your purchase of a Rapid Spray Fire Fighting Unit which is complete and ready to slip onto a ute truck or trailer for immediate action when you need it most ...

Page 4: ...hting fires or backburning 3 Select and wear appropriate Personal Protection Equipment in accordance with your own safe work practices 4 Improper or careless use of this unit can cause serious injury or death Minors should never be allowed to use this unit This unit should not be used when bystanders or animals are in the area This unit should never be used while children are in the area 5 Never l...

Page 5: ...pirator follow safe manual handling techniques don t life on your own if 20kg bend knees and keep back straight Mix chemicals if applicable and fill fire fighting unit As above spray drift chemical spillage emission or vapours or flammability weather untrained visitors Medium As above user trained in the state s chemical mixing administration course eg Chem Cert follow the relevant Environmental P...

Page 6: ... hoses and straps away from hot engine exhaust and exhaust fumes 4 Prepare the engine for use as per the engine manual supplied with your unit Ensure that the correct quantity and type of oil is used when filling the engine OPERATION Fill tank from appropriate water source For bottom filling see page 5 for instructions Open ball valve on suction hose at bottom of tank Start motor and allow to warm...

Page 7: ...sion As a guide follow the decontamination procedures below a After use the tank pump hand lance nozzle and if required hose should be flushed by running it with clean water plus a recommended cleaning fluid 2 When storing the unit ensure that it is clean and dry and store in a well ventilated place 3 If operating in areas where freezing occurs we recommend leaving anti freeze in the pump regulato...

Page 8: ...l kit for fire fighting units Includes 6m hose camlock fittings and foot strainer 25 MOTOR COVER AMHMCYE Motor cover to suit Honda motors RAPID BALL BAFFLE ARB195 ARB355 All Fire Ranger fire units are fitted standard withj the Rapid Ball Baffle system ARB195 Small Ball Baffle Ø195mm suit 400 600L 1 Ball Baffle per 7L capacity 23 ARB355 Small Ball Baffle Ø355mm suit 800 2 500L 1 Ball Baffle per 40L...

Page 9: ...n 18 CFYS25N20TC 1 3 4 nut tail 19 ARFB038R 1 1 2 brass tank fitting 20 CFVBB040F040F 40mm 1 1 2 lever ball valve 21 CFVBB040M040FBV19M 40mm 1 1 2 ball valve M F suit PFUS0400LZ not shown 22 CFNW20F 3 4 spinweld flush not shown 23 ARB195 Rapid Ball Baffle 195mm to suit 400 600 litre 24 ARB355 Rapid Ball Baffle 355mm to suit 800 2500 litre 25 AMHMCYE Motor cover to suit Honda motors 26 PTC00400FG 4...

Page 10: ...ut 6 CFBL25F2 Swivel end brass nut for hose reel 7 CFPPT25M220 25 220mm screw pipe piece poly 8 CHJCH01X100X30 Spring for FF hose reel 9 CUF14519MMX36N 36m length x 19mm fire hose with nozzle 10 CHHRB10M080 Rotating handle M10 x 80 for hose reels 11 Mounting Pack 4 x M10 Nyloc nut zinc 4 x M10 3 8 flat washer zinc 4 x M10 x 30 4 6 zinc set screw 12 CNAFP20F Poly 3 4 adjustable fire fighting nozzle...

Page 11: ... dams and rivers slipping falling drowning and use safe work practices at all times OPERATION PROCEDURE BOTTOM FILL KIT 1 Turn off engine 2 Remove camlock cap from large outlet on pump refer to visual 3 Detach the suction hose from pump and attach to top outlet refer to visual 4 Attach suction hose from bottom fill kit to suction point of pump refer to visual 5 Place foot strainer and hose into wa...

Page 12: ...Rapid Spray Fire Fighting Unit Operators Handbook 10 Rapid Spray Equipment by Rapid Spray AUSSIE FIRE CHIEF QP205SE ...

Page 13: ...00E only 1 9d Q2242 060030 Impeller for Robin DY23 DY27 only 1 10 Q1803 100130 Volute casing 1 11 Q1378 330620 Volute casing packing 1 12 Q1211 390610 Casing cover packing 1 13 Q9358 100020 Mounting flange P type 1 13 Q1378 100020 Mounting flange W type 1 14 Q018105 0825 Bolt set with spring washer 1 15 Q1803 330360 Delivery cover packing 1 16 Q1814 100090 Delivery cover packing 3 way outlet 1 16 ...

Page 14: ...to hold RAPID SPRAY not liable for claims by their customers in excess of the obligations of RAPID SPRAY expressly set forth herein NOTE All tank and spray systems must have their warranty activated by returning the warranty card located at the end of this document within 21 days of purchase by the end user The Warranty All products sold by RAPID SPRAY are guaranteed to be free from defect in mate...

Page 15: ...hoses seals and connections damaged by corrosive chemicals dirt and sand excessive heat mois ture or other environmental impacts Warranty determi nation on these type of failures will be made by RAPID SPRAY only after inspection of the failed component INABILITY UNSUITABILITY In no event shall RAPID SPRAY be liable to any person for indirect or consequential damages or for injury or commercial los...

Page 16: ...Rapid Spray Fire Fighting Unit Operators Handbook 14 Rapid Spray Equipment by Rapid Spray This page has been left blank intentionally ...

Page 17: ...u further please complete the following Purchaser s Age Up to 25 25 40 41 55 Over 55 What influenced you to purchase a Rapid Spray product Received Catalogue Better features than competitor product Newspaper advertisement Quality reliability Magazine advertisement Price Dealer recommendation Past experience with Rapid Spray products Friends recommendation Other Principal Usage Commercial farm Town...

Page 18: ...all us on 1800 011 000 or visit www rapidspray net 35 Enterprise Cres Singleton NSW 2330 PO BOX 3119 Singleton NSW 2330 Telephone 1800 011 000 Facsimile 02 6571 2951 Rapid Spray Liquid Management Systems ...

Reviews: