BH-S
ERIES
I
NSTALLATION
, O
PERATION
AND
S
ERVICE
M
ANUAL
48 of 59
For
b
est performance, the gas, electrical, thermostat
connections, t
ub
ing,
v
enting, s
u
spensions and
o
v
erall heater condition sho
u
ld
b
e inspected
thoro
u
ghly.
NOTE:
Gas flo
w
and
bu
rner ignition are among the
first things that sho
u
ld
b
e inspected.
Please
for s
u
ggested
items to inspect.
11.5 Maintenance Checklist
Installation Code and Annual Inspections:
All installation and ser
v
ice of RAPID
TM
eq
u
ipment
m
u
st
b
e performed
b
y a contractor q
u
alified in the
installation and ser
v
ice of eq
u
ipment sold and
s
u
pplied
b
y Rapid Engineering LLC and conform to
all req
u
irements set forth in the RAPID
TM
man
u
als
and all applica
b
le go
v
ernmental a
u
thorities
pertaining to the installation, ser
v
ice, operation and
la
b
eling of the eq
u
ipment.
To help facilitate optim
u
m performance and safety,
Rapid Engineering LLC recommends that a q
u
alified
contractor cond
u
ct, at a minim
u
m, ann
u
al
inspections of yo
u
r RAPID
TM
eq
u
ipment and perform
ser
v
ice
w
here necessary,
u
sing only replacement
parts sold and s
u
pplied
b
y Rapid Engineering LLC.
The Vicinity of the Heater
Do not store or
u
se flamma
b
le o
b
jects, liq
u
ids or
v
apors near the heater.
Immediately remo
v
e these items if they are present.
Vehicles and Other
Objects
Maintain the clearances to com
bu
sti
b
les.
Do not hang anything from, or place anything on, the heater.
Make s
u
re nothing is lodged
u
nderneath the reflector, in
b
et
w
een the t
ub
es or
in the decorati
v
e or protecti
v
e grilles (incl
u
ded
w
ith select models).
Immediately remo
v
e o
b
jects in
v
iolation of the clearances to com
bu
sti
b
les.
Reflector
S
u
pport reflector
w
ith reflector hanger and s
u
pport strap.
Reflector m
u
st not to
u
ch t
ub
e.
Make s
u
re there is no dirt, sagging, cracking or distortion.
Do not operate if there is sagging, cracking or distortion.
Make s
u
re reflectors are correctly o
v
erlapped.
.
Clean o
u
tside s
u
rface
w
ith a damp cloth.
Vent Pipe
Venting m
u
st
b
e intact. Using a flashlight, look for o
b
str
u
ctions, cracks on the
pipe, gaps in the sealed areas or corrosion.
The area m
u
st
b
e free of dirt and d
u
st.
Remo
v
e any car
b
on deposits or scale
u
sing a
w
ire
b
r
u
sh.
Outside Air Inlet
Inlet m
u
st
b
e intact. Look for o
b
str
u
ctions, cracks on the pipe, gaps in the
sealed areas or corrosion.
The area m
u
st
b
e free of dirt and d
u
st. Clean and reinstall as req
u
ired.
Tubes
Make s
u
re there are no cracks.
Make s
u
re t
ub
es are connected and s
u
spended sec
u
rely.
Make s
u
re there is no sagging,
b
ending or distortion.
Clean or replace as req
u
ired.
Gas Line
.
Burner Observation
Window
Make s
u
re it is clean and free of cracks or holes.
Clean and replace as req
u
ired.
Summary of Contents for BH-40
Page 2: ......
Page 4: ......
Page 6: ......
Page 51: ...SECTION 10 WIRING 45 of 59 10 3 Internal Wiring ...
Page 58: ...BH SERIES INSTALLATION OPERATION AND SERVICE MANUAL 52 of 59 ...
Page 59: ...SECTION 12 TROUBLESHOOTING 53 of 59 12 2 Manifold Gas Pressure Setting ...
Page 61: ...SECTION 13 REPLACEMENT PARTS 55 of 59 ...
Page 64: ...BH SERIES INSTALLATION OPERATION AND SERVICE MANUAL 58 of 59 ...
Page 66: ......
Page 67: ......
Page 68: ......