14
EE
–
data errors
– In certain operating conditions, the instrument may detect errors
in the data saved. These errors may compromise the correct operation of the
instrument. If the microprocessor detects a data saving error, the display shows the
message
“EE”.
If the fault persists, the controller needs to be replaced. If, on the
other hand, the message disappears, it can continue to be used. When
“EE”
error
occurs frequently and/or remains for some time, the controller should be checked,
as the original precision may not be guaranteed.
LO flashing
–
low temperature alarm. The probe has measured a temperature
lower than the set point by a value that exceeds parameter AL:
check parameters AL, Ad and A0.
The alarm is automatically reset when the temperature returns within the set limits
(see parameter AL).
HI flashing
– high temperature alarm. The probe has measured a temperature
higher than the set point by a value that exceeds parameter AH.
check parameters AH, Ad and A0.
11. NOTES
1. Attempts to repair the device on your own and not following the instructions
described in the user manual as for equipment connection and use will result
in the device malfunction.
2. The device is using natural and ecological refrigerant R-290 (propane).
Warning! In case of damage of the cooling system the refrigerator
should be immediately disconnected from the mains, any open
sources of fire located close to the unit removed and the area
carefully ventilated.
Do not use electrical appliances inside the refrigerator.
3. The manufacturer is not liable for damages resulting from the use of the device
in a manner inconsistent with the information contained in hereby user manual.