QUICK START GUIDE
en-14
unless the button is held. If held for one
second the unit increases at a rate of three
units per second. Pressing the checkmark
will move the line to the next unit to be
adjusted. If at the end it will move to the time
or date. Pressing button one (exit) will, if no
unit is selected return to the previous menu
or if a unit is selected return to start of this
page.
SERVICE MENU
The checkmark can be moved up and down
using buttons two and three. Button four
then enters the selected page. Button one
returns to the main menu. There are three
options within this menu.
Fault Log
Time to Service
Diagnostics
A service engineer can reset the time to
service.
The part numbers for service items are
stored within the memory, only numerical
digits are stored.
The first service is at 50 hours, after the first
service the interval is 250 hours.
DATA LOGGING MENU
The last 50 “Faults” that the controller finds
are recorded. When 50 faults are recorded,
the next fault that occures will overwrite the
oldest fault.
This information is retrieved using the
service tool, or can be seen on the errors
page of the service menu. The same
method of navigating pages applies, the
errors scroll with the last error always at the
top of the screen.
The fault / data record function has three
actions. Each record can contain a
maximum of 50 faults. These are as follows
Inclinometer records the slopes greater than
22°.
Engine records the engine shutdowns
caused by overheat or loss of oil pressure.
Service records hydraulic by-pass and
missed service intervals.
Service Menu
FAULT
LOG
TIME
TO
SERVICE
Diagnostics
Service required in 10 Hours
Parts required for routine service
1234 Fuel
Filter
1235 Air
Filter
1236 Engine
Oil
Filter
1237 Hydraulic
Filter
12/05/2008
13/05/2008
18/05/2008
22/06/2008
22/06/2008
VISUAL DISPLAY
13/05/2008 @ 13:05
Max Temp
-
110°C
Time above 100°C
-
17 mins