TF2048903-BA-00 English
Page
9
of
16
20180615-V1
Lighting Instructions
1
Read instruction before lighting.
2
When you are sure there are no leaks, turn
cylinder valve and regulator control valve on
hose to the closed position.
3
Reopen cylinder valve fully.
4
Have a standard match, fireplace match or
long-nosed propane lighter lit and ready to
place over the burner.
5
Light the burner from the burner top before
opening the gas supply, keeping hands and
face away from open burner.
6
Place lighter over the burner open, then
slowly open regulator valve until burner
ignites.
7
Adjust the regulator control valve for desired flame height.
8
When finished using the cooker, turn off gas cylinder valve first. It will take a few
second for the fire to go out and for the propane gas to
“bleed” from the hose and
regulator assembly. After the fire is completely out, turn regulator control valve to the
“OFF” position.
9
To re-light, repeat steps 1
– 8. Always use CAUTION as cooker will be hot.
10 If ignition does not occur in 5 seconds, turn the burner control(s) off, wait 5 minutes, and
repeat the lighting procedure.
CAUTION
If burner does not light OR if burner flame is accidentally extinguished, turn knob to OFF, wait 5
minutes, try again. If the burner does not ignite with valve open OR if burner flame goes out after
lighting, gas will continue to flow out of the burner and could accidentally ignite with risk of injury.
Burner Flame Check
Light Burner, rotate knob from HIGH to LOW. You should
see a smaller flame in LOW position than seen on HIGH.
Always check flame prior to each use. The air damper (D)
mounted on the back of your burner helps to control the
amount of primary air that mixes with the LP gas. A blue
flame with little or no yellow flame provides the best heat.
Adjust the air damper by turning it clockwise or
counterclockwise until the desired flame is achieved.
Turning LP Cooker Off
Turn all knobs to OFF position, turn LP tank OFF by turning
hand-wheel clockwise to a full stop.
Hose Assembly and Regulator Check
Cleaning and inspection of pressure regulator and hose
Match
Counterclockwise to
open the gas supply
B