background image

8

MAINTENANCE

To ensure the CB-30L Cool Boss evaporative air cooler 

releases fresh and clean air, always change the 

water when dirty and regularly clean the filter and 

cooling pad.

1.  Remove the Filter Net by removing the screw then 

press the lock. Rinse under running water to wash off dirt.

2. Pull-out the Cooling Pad. Wash the Cooling Pad under 

running water. NEVER USE PRESSURIZED WATER as 

it may damage the pad. Wash from the inner-side to the 

outside of pad (inner side is the side facing the fan  

motor).

3. Open the drainage valve to remove remaining water 

then clean the water tank thoroughly with soft cloth to 

remove dirt. Also, wash off dirt on the water sensor, water 

pump and the drainage valve.

4. Use mild soap and soft clean cloth in cleaning the 

outer body chassis.

Before using the machine, please read this manual 

and carefully operate according to the instructions:

A. 

Use the machine in the following condition:

• 

Temperature: 18ºC ~ 45ºC

• 

Water Temperature: <45ºC

• 

Electric voltage must not exceed the required volt  

             (+/-) 5%

• 

No pollution around the working area. 

 

B.

 The circuit of the machine must be properly connected 

and protected to prevent mouse bites. Trampled or over-

stretched, which may cause short circuits. Using wrong 

electric voltage of wrong socket will cause danger of 

electric shock. 

 

C.

 Do not use wrong circuit or other wire metal made of 

other materials which may cause machine malfunction or 

explosion. 

 

D

. If the CB-30L Evaporative Air Cooler is not operating 

well or may have unusual malfunction, contact distributor 

or Ranger Products immediately. 

 

E

. Always open doors and windows when using this unit. 

Keep area ventilated at all times.

 

NOTE:

 NEVER USE PRESSURIZED WATER.  

NEVER

 

SPRAY OR WASH UNIT WITH A GARDEN 

HOSE AS WATER MAY HARM MOTOR AND OTHER

ELECTRICAL SYSTEM COMPONENTS.

NOTE:

USE OF STRONG CHEMICALS THAT MAY CAUSE 

DAMAGE TO THE BODY IS NOT ADVISABLE.

KEEP AWAY FROM FIRE DURING 

TRANSPORTATION, INSTALLATION AND 

OPERATION. IF ANY ABNORMALITY  

OCCURRED DURING OPERATION,  

CONTACT BENDPAK/RANGER.

USE THIS MACHINE IN ACCORDANCE TO

THE MANUAL INSTRUCTIONS. 

ANY INCORRECT USE CAUSING THE UNIT TO 

MALFUNCTION, THE SUPPLIER/DEALER WILL 

NOT BE HELD RESPONSIBLE.

Summary of Contents for CB-30L

Page 1: ...pment must be made by the purchaser against the transportation company at the time shipment is received BE SAFE Ranger Evaporative Air Coolers are designed and built with safety in mind However proper...

Page 2: ...on to return merchandise has been received For all merchandise returned to BendPak Ranger for reasons other than warranty a 20 restocking fee and round trip shipping costs will be deducted from the cr...

Page 3: ...amaged loose or missing parts Any CB 30L air cooler that appears to be damaged in any way is found to be worn or operated abnormally must be removed from service immediately Any CB 30L evaporative air...

Page 4: ...mmable liquids or gases 14 Ensure cooler pumps are running continuously to saturate and wet media pads at all times during operation 15 ALWAYS maintain a distance of at least 50 feet from any open fla...

Page 5: ...mmed control panel with LCD display and comes with a convenient remote control Built in timer allow the unit to be programmed to turn on or off at preselected times A large 30 inch diameter fan operat...

Page 6: ...Pipe Size inch NPT fitting Back Safety Net Water Distributor Water Pipe Grille Motor Cooler Housing LCD Panel Side Panel Front Net Add Water Back Caster Front Caster Footing Water Tank Diffuser CB 30...

Page 7: ...e function of setting time Press TIMER 6 Press SWING to move the louvers side to side and help circulate cold air more efficiently 7 ION button Built in ionizer to release negative ions for cleaner ai...

Page 8: ...e must not exceed the required volt 5 No pollution around the working area B The circuit of the machine must be properly connected and protected to prevent mouse bites Trampled or over stretched which...

Page 9: ...et Change fan Change master control board Motor is not working Master control is not working Panel is not working Change master control board Change the panel The drain valve leaks water The drain val...

Page 10: ...y Relay Marboard Signal Switch Capacitors Red Orange White Live Wire AC L Ground Neutral Wire AC N Max Airflow 10595 CFM Power Consumption 550W Style Axial Water Consumption 2 65 3 96 Gal Hr Water Cap...

Page 11: ...________________________________ ____________________________________________________________________ ____________________________________________________________________ _____________________________...

Page 12: ...12...

Reviews: