BILGE PUMP SYSTEM
STE
The bilge pumps operate automatically with electronic fl oat switches even with battery switches
and breakers in the OFF position.
However, the BILGE PUMP and BILGE PUMP2 will run continuously once their switches are placed
in the on position. Monitor the outfl ow accordingly. Do not run when dry.
• Manual switches/high water alarm switch are located at the helm.
12V 1100GPH
16
WASTE SYSTEM WITH MACERATOR PUMP
STE
STE
40 Gallon Tank with standard pump out, and vent
Waste tank level can be checked by utilizing the head control panel. Please refer to your head
operations manual.
Waste tank pump out stations are widely available.
Please follow the directions carefully for the pump out equipment you are using to avoid damage
to the waste system.
Boat owner is responsible for
following all applicable laws when
using the macerator system to pump
out into the surrounding waters.
Overboard shutoff valve is accessed
under berth inline with the
macerator pump.
Valve must remain either locked, or
only able to be opened by using a
tool when not using macerator.
Example: zip tie
Macerator pump out
17
Marine
Head
Vent
Pump Out
(on deck)
Raw water
into head
Macerator Discharge
Overboard Shutoff Valve
Macerator
Waste
Tank
Multi Strainer
Thru-hull/valve
Multi Strainer