WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
15
A
Fig. 6.3
Tap Adjustment
Disconnect from the electricity supply.
When changing from one type of gas to another, the
minimum tap output must also be correct, considering
that in this position the flame must be about 4 mm
long and must remain lit even when the knob is turned
sharply from the maximum to the minimum position.
The adjustment is performed with the burner lit, as
follows:
1.
Turn the knob to the minimum position.
2.
Remove the tap knob.
3.
Turn the screw
“A”
to the correct setting
.
For LPG, tighten the adjustment screw completely.
Affix Label
Stick the LP gas label over the natural gas part of the
appliance data label.
Pressure Testing
Make sure that the appliance is gas sound.
The gas pressure can be measured at one of the
hotplate burner injectors (not the Wok burner). Lift off a
burner head. Fit the pressure gauge to the injector. Turn
on and light one of the other hotplate burners. Turn on
and push in the control knob for the burner with the
pressure gauge fitted to let gas through.
Refer to the “Connections” table in the “Technical Data” for
pressure settings
Turn off the burners. Reassemble burner top, making sure it is
reassembled in the correct way on the burner body.
Lubrication of the Gas Taps
The operations must be executed by a qualified
technician.
IMPORTANT: All intervention regarding installation
maintenance and conversion of the appliance
must be fulfilled with original factory parts. The
manufacturer declines any liability resulting from
the non-compliance of this obligation.