
WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
11
Check in the ‘Technical Data’ section at the back of the
instructions that the cooker is convertible to the gas you
want to use.
This conversion must be performed by a suitably
competent person, in accordance with these instructions
and with the local supply company requirements.
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead to
prosecution.
The conversion instructions must be used in conjunction
with the rest of the appliance instruction, in particular
for information on Standards, cooker positioning,
connection, hose suitability, etc.
When servicing or replacing gas-carrying components,
disconnect from the gas before starting, and check that
the appliance is gas sound after completion.
Do not use reconditioned or unauthorised gas controls.
Disconnect from the electricity supply before
commencing servicing.
Before electrical reconnection, check that the appliance
is electrically safe.
Injectors
Remove burner caps and heads. Remove old jets. Fit the
new jets (see Technical Data section at the back of the
book for correct jets). Reassemble in reverse order.
Tap Adjustment
Disconnect from the electricity supply.
Pull off all the control knobs. Insert a suitable small
flat screwdriver into the hole in the end of the control
spindle, and turn the bypass screw on each control
clockwise to the stop (Fig.6-1). Refit the control knob.
Affix Label
Stick the LP gas label over the natural gas part of the
appliance data label.
Pressure Testing
Make sure that the appliance is gas sound; refer to
‘Pressure Testing’
earlier in the section.
Check the operation of all the burners.
6. Conversion to LPG Gas
����������������������������������������
Fig.6-1
DocNo.071-0001 - LP gas conversion - BI hobs
Summary of Contents for RGG60
Page 1: ...RGG60 Gas Hob User Guide Installation Service Instructions U109927 02...
Page 17: ...15...
Page 18: ...16...
Page 19: ...17...
Page 20: ...www rangemaster co uk ArtNo 000 0003 CE logo DocNo 000 0001 Back cover Rangemaster...